EUVIMEDEUVIMED entdecken
Crossref

A Programmable and Printable Microbial Bioelectronic Sensor for Real‐Time and Targeted Pollutant Monitoring in Water

Xing-Yu Wang, Yi-Xuan Wang iD, Jun Ding, Xiao-Li Liu, Meng-Jie Luo, Meng Liu, Dong-Feng Liu iD, Zhi-Xiang She iD, Yang Mu iD

Angewandte Chemie International Edition · 2026

DOI: 10.1002/anie.1144662 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angewandte Chemie International Edition, 2026. Verfasst von Xing-Yu Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Advanced Environmental Technology, Department of Environmental Science and Engineering, University of Science and Technology …. Hauptthemen laut MEDLINE: Biosensing Techniques, Shewanella, Water Pollutants, Chemical, Dinitrobenzenes. Die Arbeit nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation, Postdoctoral Fellowship Program of China Postdoctoral Science Foundation project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid detection of toxic trace contaminants is critical for global water security, yet routine monitoring relies on costly, time‐consuming laboratory analyses. Microbial sensors offer a promising alternative but suffer from limited specificity, insufficient stability, and slow kinetics. Herein, we report a programmable and printable microbial bioelectronic sensor that overcomes these bottlenecks through multi‐scale chemical design. Using 2,4‐dinitrotoluene as a model pollutant, we genetically reprogrammed the extracellular electron transfer pathway of Shewanella oneidensis by coupling specific pollutant recognition to inner‐membrane cytochrome expression, thereby enabling highly specific bioelectrical detection of target pollutants. For robust deployment, these sensing microbes were encapsulated into a dual‐network hydrogel sustained by reversible hydrogen bonding, ensuring structural resilience and biocompatibility. By 3D‐printing the biosensor into a biomimetic fractal architecture, we minimized mass transport resistance, achieving a response time of 5 min, a 24‐fold acceleration over conventional counterparts. The biosensor also exhibited a low detection limit of 6.75 µg L −1 and a broad dynamic range from 20.4 to 700.0 µg L −1 ( R 2 > 0.999). Crucially, the biosensor maintained high accuracy (relative error < 4.2%) in actual wastewaters. This work establishes that the multiscale chemical design of microbial bioelectronic sensors enables real‐time, targeted pollutant monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesShewanellaWater Pollutants, ChemicalDinitrobenzenesEnvironmental Monitoring

Stichwörter der Autor:innen

3D bioprintingbioelectronic sensorextracellular electron transfergenetic engineeringwater pollution monitoring

Substanzen

Water Pollutants, Chemical2,4-dinitrotolueneDinitrobenzenes

Autor:innen und Institutionen

  • State Key Laboratory of Advanced Environmental Technology, Department of Environmental Science and Engineering, University of Science and Technology of China, Hefei, Anhui, China.
  • Key Laboratory of Environmental Remediation and Ecological Health, School of Environmental and Biological Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, China.
  • Key Laboratory of Water Pollution Control and Wastewater Reuse of Anhui Province, Anhui Provincial Key Laboratory of Environmental Pollution Control and Resource Reuse, Anhui Jianzhu University, Hefei, Anhui, China.

ORCID-Profile: Yi-Xuan Wang, Dong-Feng Liu, Zhi-Xiang She, Yang Mu

Förderung

  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation
  • Postdoctoral Fellowship Program of China Postdoctoral Science Foundation project
  • Fundamental Research Funds for the Central Universities
  • Anhui Jianzhu University

Zitieren

APA

Wang, X. Y., Wang, Y. X., Ding, J., Liu, X. L., Luo, M. J., Liu, M., Liu, D. F., She, Z. X., & Mu, Y. (2026). A Programmable and Printable Microbial Bioelectronic Sensor for Real‐Time and Targeted Pollutant Monitoring in Water. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.1144662

Vancouver

Wang XY, Wang YX, Ding J, Liu XL, Luo MJ, Liu M, et al. A Programmable and Printable Microbial Bioelectronic Sensor for Real‐Time and Targeted Pollutant Monitoring in Water. Angewandte Chemie International Edition. 2026. doi:10.1002/anie.1144662

BibTeX
@article{Wang2026,
  author = {Wang, Xing-Yu and Wang, Yi-Xuan and Ding, Jun and Liu, Xiao-Li and Luo, Meng-Jie and Liu, Meng and Liu, Dong-Feng and She, Zhi-Xiang and Mu, Yang},
  title = {A Programmable and Printable Microbial Bioelectronic Sensor for Real‐Time and Targeted Pollutant Monitoring in Water},
  journal = {Angewandte Chemie International Edition},
  year = {2026},
  doi = {10.1002/anie.1144662}
}
Kostenlos starten →