EUVIMEDEUVIMED entdecken
Open Access

Diffusion‐Weighted Imaging Fluid‐Attenuated Inversion Recovery Mismatch on Portable, Low‐Field Magnetic Resonance Imaging Among Acute Stroke Patients

Annabel Sorby-Adams iD, Jennifer Guo, Adam de Havenon, Seyedmehdi Payabvash, Gordon Sze, Nandor K Pinter, Vinay Jaikumar, Adnan Siddiqui, Steven Baldassano, Ana-Lucia Garcia-Guarniz, Julia Zabinska, Dheeraj Lalwani und 14 weitere

Annals of Neurology · 2024-08 · 96 (2) · 321-331

DOI: 10.1002/ana.26954 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Neurology, online erschienen am 13.05.2024. Verfasst von Annabel Sorby-Adams und 25 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology and the Center for Genomic Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Ischemic Stroke. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NCATS NIH HHS, NIA NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

For stroke patients with unknown time of onset, mismatch between diffusion‐weighted imaging (DWI) and fluid‐attenuated inversion recovery (FLAIR) magnetic resonance imaging (MRI) can guide thrombolytic intervention. However, access to MRI for hyperacute stroke is limited. Here, we sought to evaluate whether a portable, low‐field (LF)‐MRI scanner can identify DWI‐FLAIR mismatch in acute ischemic stroke.

Methods

Eligible patients with a diagnosis of acute ischemic stroke underwent LF‐MRI acquisition on a 0.064‐T scanner within 24 h of last known well. Qualitative and quantitative metrics were evaluated. Two trained assessors determined the visibility of stroke lesions on LF‐FLAIR. An image coregistration pipeline was developed, and the LF‐FLAIR signal intensity ratio (SIR) was derived.

Results

The study included 71 patients aged 71 ± 14 years and a National Institutes of Health Stroke Scale of 6 (interquartile range 3–14). The interobserver agreement for identifying visible FLAIR hyperintensities was high ( κ = 0.85, 95% CI 0.70–0.99). Visual DWI‐FLAIR mismatch had a 60% sensitivity and 82% specificity for stroke patients

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingIschemic StrokeHumansAgedMaleFemaleMiddle AgedAged, 80 and overStrokeMagnetic Resonance Imaging

Autor:innen und Institutionen

  • Department of Neurology and the Center for Genomic Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
  • Department of Neurology, Yale Center for Brain & Mind Health, Yale School of Medicine, New Haven, CT, USA.
  • Department of Radiology and Biomedical Imaging, Yale School of Medicine, New Haven, CT, USA.
  • Department of Radiology, Jacobs School of Medicine & Biomedical Sciences, State University of New York at Buffalo, Buffalo, NY, USA.
  • Department of Neurosurgery, Jacobs School of Medicine & Biomedical Sciences, State University of New York at Buffalo, Buffalo, NY, USA.
  • Division of Neuroradiology, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.

ORCID-Profile: Annabel Sorby-Adams, Matthew S Rosen, Kevin N Sheth

Förderung

  • NINDS NIH HHS
  • NCATS NIH HHS
  • NIA NIH HHS
  • NIMH NIH HHS
  • Fulbright Postdoctoral Fellowship
  • NIH HHS
  • NIBIB NIH HHS
  • American Heart Association and Tedy's Team Postdoctoral Fellowship

Zitieren

APA

Sorby-Adams, A., Guo, J., de Havenon, A., Payabvash, S., Sze, G., Pinter, N. K., Jaikumar, V., Siddiqui, A., Baldassano, S., Garcia-Guarniz, A. L., Zabinska, J., Lalwani, D., Peasley, E., Goldstein, J. N., Nelson, O. K., Schaefer, P. W., Wira, C. R., Pitts, J., Lee, V., …, & Kimberly, W. T. (2024). Diffusion‐Weighted Imaging Fluid‐Attenuated Inversion Recovery Mismatch on Portable, Low‐Field Magnetic Resonance Imaging Among Acute Stroke Patients. Annals of Neurology, 96(2), 321-331. https://doi.org/10.1002/ana.26954

Vancouver

Sorby-Adams A, Guo J, de Havenon A, Payabvash S, Sze G, Pinter NK, et al. Diffusion‐Weighted Imaging Fluid‐Attenuated Inversion Recovery Mismatch on Portable, Low‐Field Magnetic Resonance Imaging Among Acute Stroke Patients. Annals of Neurology. 2024;96(2):321-331. doi:10.1002/ana.26954

BibTeX
@article{SorbyAdams2024,
  author = {Sorby-Adams, Annabel and Guo, Jennifer and de Havenon, Adam and Payabvash, Seyedmehdi and Sze, Gordon and Pinter, Nandor K and Jaikumar, Vinay and Siddiqui, Adnan and Baldassano, Steven and Garcia-Guarniz, Ana-Lucia and Zabinska, Julia and Lalwani, Dheeraj and Peasley, Emma and Goldstein, Joshua N and Nelson, Olivia K and Schaefer, Pamela W and Wira, Charles R and Pitts, John and Lee, Vivien and Muir, Keith W and Nimjee, Shahid M and Kirsch, John and Iglesias, Juan Eugenio and Rosen, Matthew S and Sheth, Kevin N and Kimberly, W Taylor},
  title = {Diffusion‐Weighted Imaging Fluid‐Attenuated Inversion Recovery Mismatch on Portable, Low‐Field Magnetic Resonance Imaging Among Acute Stroke Patients},
  journal = {Annals of Neurology},
  year = {2024},
  volume = {96},
  number = {2},
  pages = {321--331},
  doi = {10.1002/ana.26954}
}