Regional gas exchange evaluation during ex vivo lung perfusion in a swine model of localized lung dysfunction
Animal Models and Experimental Medicine · 2026
DOI: 10.1002/ame2.70224 ↗Kurz gefasst
Fachartikel in der Zeitschrift Animal Models and Experimental Medicine, 2026. Verfasst von Giulia Maria Ruggeri und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Intensive Care Units 'de Gasperis' Cardio Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy. Hauptthemen laut MEDLINE: Pulmonary Gas Exchange, Lung, Perfusion. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico.
Abstract (Originalsprache)
Background
Ex vivo lung perfusion (EVLP) allows the evaluation of lungs that do not meet standard transplantation criteria. Current procedures do not permit the identification of regional functional deficits. We investigated the feasibility of assessing lobar gas exchange during EVLP in a swine model.
Methods
In five healthy swine, lungs were procured with beating heart and connected to an open‐atrium EVLP circuit. Each pulmonary vein was cannulated for lobar perfusate sampling. After baseline assessment, the left inferior bronchus (LIB) and then the left superior bronchus (LSB) were temporarily clamped to simulate localized injury. At each step, perfusate gas analyses from each vein and the left atrium (LA), lung mechanics, pulmonary hemodynamics, and computed tomography (CT) were obtained.
Results
At baseline, no differences were observed between LA and lobar samples. Occlusion of LIB and LSB produced up to 95% non‐ or poorly aerated tissue in the affected lobe, with lobar shunt increasing to 97% [88%–103%] (LIB) and 97% [78%–106%] (LSB). Corresponding lobar PaO 2 /FiO 2 fell to 47 [46–54] and 45 [43–67] mmHg, whereas LA‐mixed venous blood maintained higher values (299 [188–373] and 349 [347–377] mmHg, respectively). Bronchial occlusions caused overall significant worsening of lung function, including increased pulmonary vascular resistance, and reduction in total air lung volume and normally aerated tissue on CT scan analysis. In Left Inferior Lobe (LIL), histological samples showed significant interstitial congestion and alveolar hemorrhage.
Conclusions
Lobar‐specific perfusate gas analysis during EVLP provides accurate functional assessment and enables the localization of lung injury, potentially improving graft evaluation before transplantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesia and Intensive Care Units 'de Gasperis' Cardio Center, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
- Department of Anesthesia and Intensive Care, ASST Santi Paolo e Carlo, San Paolo University Hospital, Milan, Italy.
- Department of Thoracic Surgery, ASST Santi Paolo e Carlo, San Paolo Hospital, Milan, Italy.
- Department of Anesthesia and Intensive Care Units, IRCCS Humanitas Research Hospital, Milan, Italy.
- Pathology Unit, Fondazione IRCCS Ca' Granda-Ospedale Maggiore Policlinico, Milan, Italy.
ORCID-Profile: Matteo Montoli, Sara Pieropan, Alessandro Santini, Gianluca Lopez, Michele Battistin, Luigi Vivona, Sebastiano Maria Colombo, Stefano Ferrero, Lorenzo Rosso, Stefano Gatti, Antonio Maria Pesenti, Giacomo Grasselli, Alberto Zanella
Förderung
- Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico
Zitieren
APA
Ruggeri, G. M., Chiodaroli, E., Montoli, M., Pieropan, S., Santini, A., Lopez, G., Battistin, M., Vivona, L., Colombo, S. M., Fumagalli, J., Carlesso, E., Ferrero, S., Rosso, L., Gatti, S., Pesenti, A. M., Grasselli, G., & Zanella, A. (2026). Regional gas exchange evaluation during ex vivo lung perfusion in a swine model of localized lung dysfunction. Animal Models and Experimental Medicine. https://doi.org/10.1002/ame2.70224
Vancouver
Ruggeri GM, Chiodaroli E, Montoli M, Pieropan S, Santini A, Lopez G, et al. Regional gas exchange evaluation during ex vivo lung perfusion in a swine model of localized lung dysfunction. Animal Models and Experimental Medicine. 2026. doi:10.1002/ame2.70224
BibTeX
@article{Ruggeri2026,
author = {Ruggeri, Giulia Maria and Chiodaroli, Elena and Montoli, Matteo and Pieropan, Sara and Santini, Alessandro and Lopez, Gianluca and Battistin, Michele and Vivona, Luigi and Colombo, Sebastiano Maria and Fumagalli, Jacopo and Carlesso, Eleonora and Ferrero, Stefano and Rosso, Lorenzo and Gatti, Stefano and Pesenti, Antonio Maria and Grasselli, Giacomo and Zanella, Alberto},
title = {Regional gas exchange evaluation during ex vivo lung perfusion in a swine model of localized lung dysfunction},
journal = {Animal Models and Experimental Medicine},
year = {2026},
doi = {10.1002/ame2.70224}
}
EUVIMED