Intratracheal instillation for the testing of pulmonary toxicity in mice—Effects of instillation devices and feed type on inflammation
Animal Models and Experimental Medicine · 2025-02 · 8 (2) · 378-386
DOI: 10.1002/ame2.12503 ↗Kurz gefasst
Fachartikel in der Zeitschrift Animal Models and Experimental Medicine, online erschienen am 03.01.2025. Verfasst von Niels Hadrup und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Research Centre for the Working Environment, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Inflammation, Pneumonia, Animal Feed, Intubation, Intratracheal. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Focused Research Effort on Chemicals in the Working Environment (FFIKA) from the Danish Government.
Abstract (Originalsprache)
Background
Inhalation exposure is the gold standard when assessing pulmonary toxicity. However, it typically requires substantial amounts of test material. Intratracheal instillation is an alternative administration technique, where the test substance is suspended in a liquid vehicle and deposited into the lung via the trachea. Instillation requires minimal test material, delivers an exact dose deep into the lung, and is less labor‐intensive than inhalation exposures. However, one shortcoming is that the procedure may induce short‐term inflammation. To minimize this, we tested different modifications of the technique to identify the potential for refinement.
Methods
First, we tested whether previous findings of increased inflammation could be confirmed. Next, we tested whether instillation with a disposable 1 mL syringe with ball‐tipped steel‐needle (Disposable‐syringe/steel‐needle) induced less inflammation than the use of our standard set‐up, a 250 μL reusable glass syringe with a disposable plastic catheter (Glass‐syringe/plastic‐catheter). Finally, we tested if access to pelleted and liquid feed prior to instillation affected inflammation. We evaluated inflammation by neutrophil numbers in bronchoalveolar fluid 24 h post‐exposure.
Results
Vehicle‐instilled mice showed a small increase in neutrophil numbers compared to untreated mice. Neutrophil numbers were slightly elevated in the groups instilled with Disposable‐syringe/steel‐needle; an interaction with feed type indicated that the increase in neutrophils was more pronounced in combination with feed pellets compared to liquid feed. We found no difference between the feed types when using the Glass‐syringe/plastic‐catheter combination.
Conclusion
The Glass‐syringe/plastic‐catheter combination induced the least exposure‐related inflammation, confirming this as a preferred instillation procedure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Research Centre for the Working Environment, Copenhagen, Denmark.
- Research Group for Risk-Benefit, National Food Institute, Technical University of Denmark, Copenhagen, Denmark.
- Department of Public Health, University of Copenhagen, Copenhagen, Denmark.
- National Food Institute, Technical University of Denmark, Copenhagen, Denmark.
ORCID-Profile: Niels Hadrup
Förderung
- Focused Research Effort on Chemicals in the Working Environment (FFIKA) from the Danish Government
Zitieren
APA
Hadrup, N., Guldbrandsen, M., Terrida, E., Bendtsen, K. M. S., Hougaard, K. S., Jacobsen, N. R., & Vogel, U. (2025). Intratracheal instillation for the testing of pulmonary toxicity in mice—Effects of instillation devices and feed type on inflammation. Animal Models and Experimental Medicine, 8(2), 378-386. https://doi.org/10.1002/ame2.12503
Vancouver
Hadrup N, Guldbrandsen M, Terrida E, Bendtsen KMS, Hougaard KS, Jacobsen NR, et al. Intratracheal instillation for the testing of pulmonary toxicity in mice—Effects of instillation devices and feed type on inflammation. Animal Models and Experimental Medicine. 2025;8(2):378-386. doi:10.1002/ame2.12503
BibTeX
@article{Hadrup2025,
author = {Hadrup, Niels and Guldbrandsen, Michael and Terrida, Eva and Bendtsen, Katja M S and Hougaard, Karin S and Jacobsen, Nicklas R and Vogel, Ulla},
title = {Intratracheal instillation for the testing of pulmonary toxicity in mice—Effects of instillation devices and feed type on inflammation},
journal = {Animal Models and Experimental Medicine},
year = {2025},
volume = {8},
number = {2},
pages = {378--386},
doi = {10.1002/ame2.12503}
}
EUVIMED