EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Tissue Doppler imaging of the diaphragm and outcome of weaning from mechanical ventilation

Tissue-Doppler-Bildgebung des Zwerchfells und Outcome des Weanings von der mechanischen Beatmung

Shaobo Xin iD, Yingjia Li, Rui Liu, Xiaozhen Liu, Shaoqing Cai

Australasian Journal of Ultrasound in Medicine · 2024-08 · 27 (3) · 159-166

DOI: 10.1002/ajum.12389 ↗

Auf einen Blick

Bei 89 beatmeten Erwachsenen sagten Zwerchfell-Parameter der Tissue-Doppler-Bildgebung das Weaning-Outcome mit AUCs von 0,74 bis 0,86 voraus.

Fragestellung

Ob Tissue-Doppler-Parameter des Zwerchfells das Weaning-Outcome bei mechanisch beatmeten Erwachsenen vorhersagen können.

Methode

Studie mit 89 erwachsenen Patient:innen; nach 30 min Spontanatmungsversuch wurden Zwerchfell-Parameter per Tissue-Doppler-Bildgebung gemessen und mit dem Weaning-Outcome verglichen.

Ergebnisse

61 Patient:innen hatten erfolgreiches Weaning, 28 ein erfolgloses. Peak contractions velocity, peak relaxation velocity, contraction acceleration und relaxation acceleration waren im erfolglosen Weaning signifikant höher; AUCs: 0,81, 0,85, 0,74 und 0,86.

Schlussfolgerung der Autor:innen

Die ultrasonografischen Tissue-Doppler-Variablen des Zwerchfells können als Prädiktoren für das Weaning von der mechanischen Beatmung dienen und beim Timing unterstützen.

Kernaussagen

  • 89 erwachsene Patient:innen unter mechanischer Beatmung
  • Zwerchfell-Parameter nach 30 min Spontanatmungsversuch gemessen
  • AUCs der Parameter: 0,74 bis 0,86

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Fachartikel in der Zeitschrift Australasian Journal of Ultrasound in Medicine, online erschienen am 06.05.2024. Verfasst von Shaobo Xin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Ultrasonics, Nanfang Hospital Southern Medical University No. 1023, South Shatai Road, Baiyun District Guangzhou 510515 China. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to employ tissue Doppler imaging to monitor diaphragmatic peak velocity and acceleration during contraction and relaxation in mechanically ventilated patients, with the objective of assessing the potential utility of this technique in predicting weaning outcomes.

Methods

A total of 89 adult subjects were recruited in this study. After 30 min of spontaneous breathing trial, the diaphragm motion parameters, including peak contraction velocity, peak relaxation velocity, contraction acceleration and relaxation acceleration, were measured in real time using tissue Doppler imaging. According to the results of weaning, the patients were divided into successful weaning group and failed weaning group. The differences of diaphragmatic tissue Doppler imaging monitoring indicators between the two groups were analysed, and the receiver operating characteristic curve was drawn to analyse the value of each ultrasound parameter in predicting weaning.

Results

In the successful weaning group, there were 61 subjects, while in the failed weaning group, there were 28 subjects. The peak contraction velocity, peak relaxation velocity, contraction acceleration and relaxation acceleration of the diaphragm were significantly higher in the failed weaning group compared to the successful weaning group (P < 0.05). The area under the curve of diaphragmatic peak contraction velocity, peak relaxation velocity, diaphragmatic contraction acceleration and diaphragmatic relaxation acceleration were 0.81 (0.72–0.91), 0.85 (0.77–0.93), 0.74 (0.63–0.86) and 0.86 (0.78–0.94), respectively.

Conclusions

The diaphragm ultrasonic tissue Doppler imaging variables can serve as predictive indicators for weaning mechanical ventilation in patients, thus providing an effective tool to assist critical care physicians in determining the optimal timing for weaning mechanical ventilation.

Schlagwörter

Stichwörter der Autor:innen

diaphragm ultrasoundmechanical ventilation weaning predictiontissue Doppler imaging technique

Autor:innen und Institutionen

  • Department of Medical Ultrasonics, Nanfang Hospital Southern Medical University No. 1023, South Shatai Road, Baiyun District Guangzhou 510515 China.
  • Intensive Care Unit Zhongshan City People's Hospital No. 2, Sunwen East Road Zhongshan Guangdong Province 528403 China.
  • Department of Medical Ultrasonics Zhongshan City People's Hospital No. 2, Sunwen East Road Zhongshan Guangdong Province 528403 China.

ORCID-Profile: Shaobo Xin

Zitieren

APA

Xin, S., Li, Y., Liu, R., Liu, X., & Cai, S. (2024). Tissue Doppler imaging of the diaphragm and outcome of weaning from mechanical ventilation. Australasian Journal of Ultrasound in Medicine, 27(3), 159-166. https://doi.org/10.1002/ajum.12389

Vancouver

Xin S, Li Y, Liu R, Liu X, Cai S. Tissue Doppler imaging of the diaphragm and outcome of weaning from mechanical ventilation. Australasian Journal of Ultrasound in Medicine. 2024;27(3):159-166. doi:10.1002/ajum.12389

BibTeX
@article{Xin2024,
  author = {Xin, Shaobo and Li, Yingjia and Liu, Rui and Liu, Xiaozhen and Cai, Shaoqing},
  title = {Tissue Doppler imaging of the diaphragm and outcome of weaning from mechanical ventilation},
  journal = {Australasian Journal of Ultrasound in Medicine},
  year = {2024},
  volume = {27},
  number = {3},
  pages = {159--166},
  doi = {10.1002/ajum.12389}
}
Kostenlos starten →