EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparability of CT and μCT ‐Extracted Femoral Diaphyseal Data in Primates

Alessandra Vecino Gazabón iD, Ashley S Hammond, Marine Cazenave, Ariel N Barrera, Eva-Mercè Fuentes, Carrie S Mongle iD, Frederick E Grine iD, Antonio Profico, Christopher B Ruff iD

American Journal of Biological Anthropology · 2026-05 · 190 (1)

DOI: 10.1002/ajpa.70268 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Biological Anthropology, online erschienen am 11.05.2026. Verfasst von Alessandra Vecino Gazabón und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Anthropology, American Museum of Natural History, New York, USA. Hauptthemen laut MEDLINE: Femur, Diaphyses, Tomography, X-Ray Computed, X-Ray Microtomography. Die Arbeit nennt 75 Literaturangaben. Gefördert von: Richard Gilder Graduate School at American Museum of Natural History, National Science Foundation, Leakey Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The increased use of medical CT and μCT for internal analyses of primate bones has led to studies combining both data types to maximize sample sizes. However, comparability of data between modalities has yet to be demonstrated. Here, we test whether CT and μCT data from the primate femoral diaphysis can be confidently combined. Materials and Methods Femora from 17 specimens ( Pan, Gorilla, Pongo, Hylobates, Ateles, Lagothrix, Mandrillus , Pithecia ) were scanned using both CT modalities. Six segmentation methods were evaluated: Manual, 1/3 and 2/3 of maximum value, Full‐Width‐at‐Half‐Maximum, Kohler method, and Buie method in Dragonfly 3D World. The R package ‘morphomap’ was used to extract cortical bone thicknesses and calculate cross‐sectional geometric (CSG) properties in cross sections from 80% (proximal) to 20% (distal) of femoral biomechanical length. Percent error was calculated by property and location. Linear regressions evaluated body mass as a predictor of error, and correction factors were developed using regression coefficients and location‐specific mean errors.

Results

Medical CT consistently underestimated most properties relative to μCT, while cortical thickness and CA were generally overestimated. The greatest percent errors occurred at distal and proximal diaphyseal locations in most comparisons. Regressions showed significant associations between body mass and error at distal sites. Application of regression‐based and mean percent corrections reduced error to acceptable ranges.

Discussion

Body size and segmentation method significantly impact comparability between medical CT and μCT in cortical thickness and CSG data. Applying location‐ and property‐specific corrections improves measurement reliability in mixed‐modality datasets and enhances comparisons across taxa.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FemurDiaphysesTomography, X-Ray ComputedX-Ray MicrotomographyPrimatesAnimalsFemaleMale

Stichwörter der Autor:innen

cortical bone thicknesscross‐sectional propertieserror studymicro‐CT

Autor:innen und Institutionen

  • Division of Anthropology, American Museum of Natural History, New York, USA.
  • New York Consortium in Evolutionary Primatology, New York, USA.
  • Richard Gilder Graduate School at the American Museum of Natural History, New York, USA.
  • Institut Català de Paleontologia Miquel Crusafont (ICP-CERCA), Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain.
  • Department of Human Origins, Max Planck Institute for Evolutionary Anthropology, Leipzig, Germany.

ORCID-Profile: Alessandra Vecino Gazabón, Carrie S Mongle, Frederick E Grine, Christopher B Ruff

Förderung

  • Richard Gilder Graduate School at American Museum of Natural History
  • National Science Foundation
  • Leakey Foundation
  • Bernard and Anne Spitzer Charitable Trust
  • Bernard and Anne Spitzer Foundation

Zitieren

APA

Vecino Gazabón, A., Hammond, A. S., Cazenave, M., Barrera, A. N., Fuentes, E. M., Mongle, C. S., Grine, F. E., Profico, A., & Ruff, C. B. (2026). Comparability of CT and μCT ‐Extracted Femoral Diaphyseal Data in Primates. American Journal of Biological Anthropology, 190(1). https://doi.org/10.1002/ajpa.70268

Vancouver

Vecino Gazabón A, Hammond AS, Cazenave M, Barrera AN, Fuentes EM, Mongle CS, et al. Comparability of CT and μCT ‐Extracted Femoral Diaphyseal Data in Primates. American Journal of Biological Anthropology. 2026;190(1). doi:10.1002/ajpa.70268

BibTeX
@article{VecinoGazabn2026,
  author = {Vecino Gazabón, Alessandra and Hammond, Ashley S and Cazenave, Marine and Barrera, Ariel N and Fuentes, Eva-Mercè and Mongle, Carrie S and Grine, Frederick E and Profico, Antonio and Ruff, Christopher B},
  title = {Comparability of CT and μCT ‐Extracted Femoral Diaphyseal Data in Primates},
  journal = {American Journal of Biological Anthropology},
  year = {2026},
  volume = {190},
  number = {1},
  doi = {10.1002/ajpa.70268}
}
Kostenlos starten →