EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Measurement Error in Osteometric, Photographic, and Virtual Methodologies to Quantify the Torsional Profile of the Lower Limb

Jessica S Wollmann-Reynolds iD, Audrey Mees, Bence Viola, Michelle E Cameron

American Journal of Biological Anthropology · 2025

DOI: 10.1002/ajpa.70154 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Biological Anthropology, 2025. Verfasst von Jessica S Wollmann-Reynolds und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anthropology, University of Toronto, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Photography, Anthropometry, Lower Extremity. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The torsional profile of the lower limb consists of femoral torsion, tibial torsion, and talar neck angle. Due to high levels of inter‐individual variation and a lack of defining landmarks, these variables are difficult to precisely measure. It is important to ensure torsional profile measurement methodologies are repeatable, so that studies evaluating these variables can be compared. Materials and Methods Two observers collected torsional profile and linear measurements from the femur, tibia, and talus of 20 individuals using osteometric, photographic, and virtual methodologies. Intra‐ and interobserver error were assessed using the technical error of measurement (TEM), %TEM, and coefficient of reliability. Comparability between methods was evaluated using correlations, reduced major axis regression, and reduced mean squared error. Two methods for measuring the torsional profile were compared: a landmark method and a shape‐fitting method.

Results

Observer error was low for linear measurements. Torsional profile measurements have higher intra‐ and interobserver error and lower comparability between methods than linear measurements. Shape‐fitting methods for femoral torsion lowered observer error but did not improve methodological comparability. Shape‐fitting methods for tibial torsion did not substantially alter observer error but improved method comparability. Shape‐fitting methods for talar neck angle greatly improved method comparability, but not observer error.

Discussion

Linear measurements have low observer error and are highly comparable between osteometric and virtual methods. There is greater observer error and lower comparability between measurement modalities for angular measurements. Shape‐fitting is a promising way to reduce observer error when measuring the torsional profile.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotographyAnthropometryLower ExtremityHumansMaleFemaleAdultTibiaFemurYoung AdultReproducibility of ResultsObserver Variation

Stichwörter der Autor:innen

femoral torsionobserver errortalar neck angletibial torsionvirtual anthropology

Autor:innen und Institutionen

  • Department of Anthropology, University of Toronto, Toronto, ON, Canada.

ORCID-Profile: Jessica S Wollmann-Reynolds

Zitieren

APA

Wollmann-Reynolds, J. S., Mees, A., Viola, B., & Cameron, M. E. (2025). Measurement Error in Osteometric, Photographic, and Virtual Methodologies to Quantify the Torsional Profile of the Lower Limb. American Journal of Biological Anthropology. https://doi.org/10.1002/ajpa.70154

Vancouver

Wollmann-Reynolds JS, Mees A, Viola B, Cameron ME. Measurement Error in Osteometric, Photographic, and Virtual Methodologies to Quantify the Torsional Profile of the Lower Limb. American Journal of Biological Anthropology. 2025. doi:10.1002/ajpa.70154

BibTeX
@article{WollmannReynolds2025,
  author = {Wollmann-Reynolds, Jessica S and Mees, Audrey and Viola, Bence and Cameron, Michelle E},
  title = {Measurement Error in Osteometric, Photographic, and Virtual Methodologies to Quantify the Torsional Profile of the Lower Limb},
  journal = {American Journal of Biological Anthropology},
  year = {2025},
  doi = {10.1002/ajpa.70154}
}
Kostenlos starten →