EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Contact‐Free Human‐Machine Interfaces via Printed Thermopile Infrared Arrays

Zirui Wang iD, Nan Luo iD, Amrutha Bose iD, Muhammad Irfan Khan iD, Jiayi Liu, Leon Viktor Klinder, Leonard Franke, Mohamed Hussein iD, Uli Lemmer iD, Md Mofasser Mallick iD

Advanced Science · 29.10.2026

DOI: 10.1002/advs.78569 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 29.10.2026. Verfasst von Zirui Wang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Light Technology Institute, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council, Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany´s Excellence Strategy via the Excellence Cluster 3D Matter Made to Order.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Human‐machine interfaces (HMIs) are evolving as key components for advanced sensing in communication and control systems. In particular, contact‐free HMIs can facilitate unique advantages in hygiene, durability, and non‐destructive sensing. However, spatially resolved sensing platforms remain challenging using bulk approaches. Here, we report flexible infrared interface arrays (TIA1 and TIA2) with ≥10 pixels that exploit the photo‐thermoelectric (PTE) infrared sensing properties of Bi‐Te‐based thermoelectric (TE) materials via a dual‐stage energy conversion process: radiation‐to‐thermal, followed by thermal‐to‐electric. The p‐ and n‐type TE materials and electrodes were printed on polyimide to fabricate TIAs. After encapsulation with a black absorber, radially patterned silver mirrors are printed on the outer part of the pixels using aerosol jet‐printing to partially shield each thermocouple. This induces a localized temperature gradient, hence an output voltage via the Seebeck effect under infrared illumination. The pixels exhibit responsivities of 0.7 VW −1 (TIA1) and 0.9 VW −1 (TIA2), respectively, under CO 2 laser irradiation (10.6 µm), with pixel‐to‐pixel variation within ± 10%. The TIAs were demonstrated as non‐contact handwriting and dialing interfaces, converting human gestures into digital signals. These results pave the way for a self‐powered and contactless interface for future human–machine interaction technologies.

Schlagwörter

Stichwörter der Autor:innen

Bi2Te3Seebeck effecthuman‐machine‐interactioninfrared sensingprinted thermoelectrics

Autor:innen und Institutionen

  • Light Technology Institute, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
  • Institute of Microstructure Technology, Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany.
  • varmo GmbH, Eggenstein-Leopoldshafen, Germany.
  • Department of Physics, Faculty of Science, Ain Shams University, Abbassia, Cairo, Egypt.

ORCID-Profile: Zirui Wang, Nan Luo, Amrutha Bose, Muhammad Irfan Khan, Mohamed Hussein, Uli Lemmer, Md Mofasser Mallick

Förderung

  • European Research Council
  • Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany´s Excellence Strategy via the Excellence Cluster 3D Matter Made to Order

Zitieren

APA

Wang, Z., Luo, N., Bose, A., Khan, M. I., Liu, J., Klinder, L. V., Franke, L., Hussein, M., Lemmer, U., & Mallick, M. M. (2026). Contact‐Free Human‐Machine Interfaces via Printed Thermopile Infrared Arrays. Advanced Science. https://doi.org/10.1002/advs.78569

Vancouver

Wang Z, Luo N, Bose A, Khan MI, Liu J, Klinder LV, et al. Contact‐Free Human‐Machine Interfaces via Printed Thermopile Infrared Arrays. Advanced Science. 2026. doi:10.1002/advs.78569

BibTeX
@article{Wang2026,
  author = {Wang, Zirui and Luo, Nan and Bose, Amrutha and Khan, Muhammad Irfan and Liu, Jiayi and Klinder, Leon Viktor and Franke, Leonard and Hussein, Mohamed and Lemmer, Uli and Mallick, Md Mofasser},
  title = {Contact‐Free Human‐Machine Interfaces via Printed Thermopile Infrared Arrays},
  journal = {Advanced Science},
  year = {2026},
  doi = {10.1002/advs.78569}
}
Kostenlos starten →