EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Thermally Degradable Biocompatible Hydrogel as Transient Encapsulation Coating for Implantable Sensors

Francesca Persano iD, Eleonora Vandini iD, Eleonora Daini iD, Antonietta Vilella iD, Daniela Giuliani, Leonardo Lamanna iD, Marco Friuli iD, Christian Demitri iD, Laura Pecoraro iD, Amilcare Barca iD, Tiziano Verri iD, Cosimino Malitesta und 3 weitere

Advanced Science · 2026-05 · 13 (30)

DOI: 10.1002/advs.202517202 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 16.04.2026. Verfasst von Francesca Persano und 14 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, Lecce…. Hauptthemen laut MEDLINE: Coated Materials, Biocompatible, Absorbable Implants, Biocompatible Materials, Hydrogels. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union Horizon Europe Programme, HORIZON EUROPE Framework Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Implantable sensors are redefining real‐time, continuous physiological monitoring and hold great promise for personalized medicine. Yet, their clinical application is often hindered by the lack of effective encapsulation materials that simultaneously ensure environmental exposure and protect sensor components, thereby preserving signal fidelity. Although hydrogel‐based systems offer promising features such as biological tissue‐like mechanics and biocompatibility, their use as sensor coatings remains limited. Notably, despite growing interest in bioresorbable implant technologies, few coating systems offer controlled, on‐demand degradability, which represents a key requirement to avoid possible misalignment between coating dissolution rate and sensor lifetime. Here, we present a thermoresponsive hydrogel, consisting of methylcellulose, polyethylene glycol and polyacrylic acid (MC/PEG/PAA), demonstrating its high suitability as a transient encapsulating coating. The system, assembled by physical cross‐linking without using toxic reagents, and extensively characterized in terms of thermal responsiveness, swelling behavior, stability, and mechanical performance, exhibited reversible dissolution upon a mild temperature drop (from ≈37°C to ≈25°C), which was conveniently used to easily enable its degradation under physiological conditions. The hydrogel ability to act as a coating was demonstrated via the encapsulation of a fluorescent model device, confirming its optical transparency and signal‐transmission capability. In vitro studies indicated the hydrogel potential to mitigate inflammatory response, while in vivo biocompatibility, assessed in mice, revealed no signs of systemic toxicity or behavioral changes post‐implantation. Additionally, the hydrogel exhibited safe in vivo biodegradation upon a slight local temperature decrease, completely dissolving within few minutes. The developed coating, integrating good optical transparency, ease of fabrication, and in vivo safety with on‐demand, controllable degradation upon an external low‐temperature stimulus, represents a substantial advancement toward next‐generation bioresorbable implantable devices and paves the way for driving successful transformation in the field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coated Materials, BiocompatibleAbsorbable ImplantsBiocompatible MaterialsHydrogelsProstheses and ImplantsAnimalsMicePolyethylene GlycolsTemperature

Stichwörter der Autor:innen

biodegradable deviceimplantable sensorprotective coatingstimuli‐responsive materialthermo‐reversible encapsulating coating

Substanzen

Coated Materials, BiocompatibleBiocompatible MaterialsHydrogelsPolyethylene Glycols

Autor:innen und Institutionen

  • Laboratory of Analytical Chemistry, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, Lecce, Italy.
  • Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, via G. Campi 287, Modena, Italy.
  • Department of Engineering for Innovation, Campus Ecotekne, University of Salento, Lecce, Italy.
  • Department of Experimental Medicine, University of Salento, Lecce, Italy.
  • Laboratory of Applied Physiology, Department of Biological and Environmental Sciences and Technologies (Di.S.Te.B.A.), University of Salento, Lecce, Italy.
  • Laboratory of Applied Physiology, Department of Experimental Medicine (Di.Me.S.), University of Salento, Lecce, Italy.

ORCID-Profile: Francesca Persano, Eleonora Vandini, Eleonora Daini, Antonietta Vilella, Leonardo Lamanna, Marco Friuli, Christian Demitri, Laura Pecoraro, Amilcare Barca, Tiziano Verri, Martina Corsi, Giuseppe Barillaro, Elisabetta Mazzotta

Förderung

  • European Union Horizon Europe Programme
  • HORIZON EUROPE Framework Programme

Zitieren

APA

Persano, F., Vandini, E., Daini, E., Vilella, A., Giuliani, D., Lamanna, L., Friuli, M., Demitri, C., Pecoraro, L., Barca, A., Verri, T., Malitesta, C., Corsi, M., Barillaro, G., & Mazzotta, E. (2026). Thermally Degradable Biocompatible Hydrogel as Transient Encapsulation Coating for Implantable Sensors. Advanced Science, 13(30). https://doi.org/10.1002/advs.202517202

Vancouver

Persano F, Vandini E, Daini E, Vilella A, Giuliani D, Lamanna L, et al. Thermally Degradable Biocompatible Hydrogel as Transient Encapsulation Coating for Implantable Sensors. Advanced Science. 2026;13(30). doi:10.1002/advs.202517202

BibTeX
@article{Persano2026,
  author = {Persano, Francesca and Vandini, Eleonora and Daini, Eleonora and Vilella, Antonietta and Giuliani, Daniela and Lamanna, Leonardo and Friuli, Marco and Demitri, Christian and Pecoraro, Laura and Barca, Amilcare and Verri, Tiziano and Malitesta, Cosimino and Corsi, Martina and Barillaro, Giuseppe and Mazzotta, Elisabetta},
  title = {Thermally Degradable Biocompatible Hydrogel as Transient Encapsulation Coating for Implantable Sensors},
  journal = {Advanced Science},
  year = {2026},
  volume = {13},
  number = {30},
  doi = {10.1002/advs.202517202}
}
Kostenlos starten →