DFT‐Guided Design of a Multi‐Enzyme Mimetic High‐Entropy Nanozyme for Cascaded Glutathione Detection and Point‐of‐Care Testing

Hua Lin, Li Ke, Shuran Wang, Ruoke Li, Shengmin Zhou, Yueling Liu iD, Huan Pang iD

Advanced Science · 2026-01 · 13 (4)

DOI: 10.1002/advs.202515765 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 05.11.2025. Verfasst von Hua Lin und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Bioreactor Engineering, School of Biotechnology, East China University of Science and Technology, Shanghai, 200237, P. R. Chi…. Hauptthemen laut MEDLINE: Glutathione, Point-of-Care Testing, Biosensing Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, State Key Laboratory of Life Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Despite of the various advantages of Prussian blue analogs (PBA), most of the previous studies rely on conventional empirical and trial‐and‐error methods for identifying the effective catalytic activity. Theory‐guided design using predictive models is leading a new revolution in the field of nanozymes, which has yet to focus on PBA. Herein, a series of PBAs, including binary, ternary, quaternary, quinary, and high‐entropy, are first investigated by density functional theory (DFT) calculations. Both DFT and experimental results prove the superior catalytic activity of high‐entropy than medium‐ and low‐entropy PBAs, mainly owing to the enhanced d ‐band centers near the Fermi energy level ( E F ). The proposed high‐entropy PBA oxide (HEO, MnCoNiCuZnFe) demonstrates multi‐enzymatic activities. To achieve the colorimetric detection of glutathione (GSH), a colorimetric system with 3,3′,5,5′‐tetramethylbenzidine (TMB) and H 2 O 2 is employed and exhibits a low detection limit, excellent selectivity, remarkable reusability, and long‐term stability. Moreover, DFT calculations elucidate the electronic structure by revealing the Gibbs free energy of H 2 O 2 dissociation on individual transition‐metal sites. Additionally, a microfluidic paper‐based analytical device for the point‐of‐care testing (POCT) of GSH is successfully developed. This study not only provides a rational design strategy for multi‐metallic nanomaterials, but also expands the application of high‐entropy PBA nanozymes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GlutathionePoint-of-Care TestingBiosensing TechniquesDensity Functional TheoryEntropyColorimetryCatalysisHydrogen PeroxideFerrocyanidesBenzidines

Stichwörter der Autor:innen

Prussian blue analoguescolorimetricglutathionehigh‐entropy nanozymemicrofluidic paper

Substanzen

GlutathioneHydrogen Peroxide3,3',5,5'-tetramethylbenzidineFerrocyanidesBenzidines

Autor:innen und Institutionen

  • State Key Laboratory of Bioreactor Engineering, School of Biotechnology, East China University of Science and Technology, Shanghai, 200237, P. R. China.
  • School of Chemistry and Chemical Engineering, Yangzhou University, Jiangsu, 225009, P. R. China.

ORCID-Profile: Yueling Liu, Huan Pang

Förderung

  • National Natural Science Foundation of China
  • State Key Laboratory of Life Science

Zitieren

APA

Lin, H., Ke, L., Wang, S., Li, R., Zhou, S., Liu, Y., & Pang, H. (2026). DFT‐Guided Design of a Multi‐Enzyme Mimetic High‐Entropy Nanozyme for Cascaded Glutathione Detection and Point‐of‐Care Testing. Advanced Science, 13(4). https://doi.org/10.1002/advs.202515765

Vancouver

Lin H, Ke L, Wang S, Li R, Zhou S, Liu Y, et al. DFT‐Guided Design of a Multi‐Enzyme Mimetic High‐Entropy Nanozyme for Cascaded Glutathione Detection and Point‐of‐Care Testing. Advanced Science. 2026;13(4). doi:10.1002/advs.202515765

BibTeX
@article{Lin2026,
  author = {Lin, Hua and Ke, Li and Wang, Shuran and Li, Ruoke and Zhou, Shengmin and Liu, Yueling and Pang, Huan},
  title = {DFT‐Guided Design of a Multi‐Enzyme Mimetic High‐Entropy Nanozyme for Cascaded Glutathione Detection and Point‐of‐Care Testing},
  journal = {Advanced Science},
  year = {2026},
  volume = {13},
  number = {4},
  doi = {10.1002/advs.202515765}
}
Kostenlos starten →