EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Bioactive Silk Sericin/Bioceramic Nerve Guidance Conduit for Effective Repair of Long‐Gap Transected Peripheral Nerve Injury through Regulating Schwann Cells

Qiangfei Su, Jian Wang, Yu Song, Zhaowenbin Zhang, Bo Cai, Xiakeerzhati Xiaohalati, Jingwei Liu, Haozhe Li, Zheng Wang, Jiang Chang, Lin Wang iD

Advanced Science · 2025-10 · 12 (38)

DOI: 10.1002/advs.202507241 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 08.07.2025. Verfasst von Qiangfei Su und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China. Hauptthemen laut MEDLINE: Schwann Cells, Peripheral Nerve Injuries, Sericins, Nerve Regeneration. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 117 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China Programs, Hubei Province Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Schwann cells are pivotal in generating a pro‐regenerative microenvironment for long‐gap peripheral nerve injury (PNI) repair via their orchestrated behaviors, including cell migration, proliferation, and secretion. Bioceramics can release bioactive ions to regulate “repair” cells for regenerating damaged tissues. Herein, bioceramic akermanite (AT) is screened and found to significantly enhance Schwann cell proliferation, migration, and secretion by activating the PI3K/AKT and MAPK/ERK signaling pathways. Integration with silk sericin (SS), a natural biomaterial possessing excellent bioactivity, promotes the release of Ca and Mg from AT, synergistically enhancing Schwann cell pro‐regenerative behaviors and accelerating axon elongation. The AT‐SS composite conduit effectively restores nerve structure and function in a 13 mm transected PNI. Compared with commercial eton conduit, AT‐SS conduit promotes axons and myelin sheaths regeneration, improves nerve conduction, and effectively alleviates gastrocnemius muscle atrophy. The AT‐SS conduit achieves autograft‐comparable behavioral recovery as evidenced by the paw withdrawal latency, hind limb grip force, and sciatic function index. The excellent degradation and biosafety of AT‐SS conduit indicate its potential for clinical translation. This study introduces an ion‐based therapeutic approach for enhancing the pro‐regenerative functions of Schwann cells, and provides novel insights and strategies for clinically managing long‐gap PNI and other nerve tissue injuries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Schwann CellsPeripheral Nerve InjuriesSericinsNerve RegenerationGuided Tissue RegenerationAnimalsRatsRats, Sprague-DawleyBiocompatible MaterialsMaleCell Proliferation

Stichwörter der Autor:innen

Schwann cell functionakermaniteion‐based therapylong‐gap nerve regenerationnerve guidance conduitsilk sericin

Substanzen

SericinsBiocompatible Materials

Autor:innen und Institutionen

  • Department of Clinical Laboratory, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
  • Hubei Key Laboratory of Regenerative Medicine and Multi-disciplinary Translational Research, Hubei Provincial Engineering Research Center of Clinical Laboratory and Active Health Smart Equipment, Research Center for Tis…
  • Center for Science & Technology Development, Shenzhen Huazhong University of Science and Technology Research Institute, Shenzhen, 518057, China.
  • State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.
  • Zhejiang Engineering Research Center for Tissue Repair Materials, Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, 325000, China.
  • Department of Gastrointestinal Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.

ORCID-Profile: Lin Wang

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China Programs
  • Hubei Province Natural Science Foundation
  • Guangdong Province Natural Science Foundation
  • Hubei Province Science and Technology Innovation Team Project
  • Major Scientific and Technological Innovation Projects of Hubei Province
  • National Basic Research Program of China

Zitieren

APA

Su, Q., Wang, J., Song, Y., Zhang, Z., Cai, B., Xiaohalati, X., Liu, J., Li, H., Wang, Z., Chang, J., & Wang, L. (2025). Bioactive Silk Sericin/Bioceramic Nerve Guidance Conduit for Effective Repair of Long‐Gap Transected Peripheral Nerve Injury through Regulating Schwann Cells. Advanced Science, 12(38). https://doi.org/10.1002/advs.202507241

Vancouver

Su Q, Wang J, Song Y, Zhang Z, Cai B, Xiaohalati X, et al. Bioactive Silk Sericin/Bioceramic Nerve Guidance Conduit for Effective Repair of Long‐Gap Transected Peripheral Nerve Injury through Regulating Schwann Cells. Advanced Science. 2025;12(38). doi:10.1002/advs.202507241

BibTeX
@article{Su2025,
  author = {Su, Qiangfei and Wang, Jian and Song, Yu and Zhang, Zhaowenbin and Cai, Bo and Xiaohalati, Xiakeerzhati and Liu, Jingwei and Li, Haozhe and Wang, Zheng and Chang, Jiang and Wang, Lin},
  title = {Bioactive Silk Sericin/Bioceramic Nerve Guidance Conduit for Effective Repair of Long‐Gap Transected Peripheral Nerve Injury through Regulating Schwann Cells},
  journal = {Advanced Science},
  year = {2025},
  volume = {12},
  number = {38},
  doi = {10.1002/advs.202507241}
}
Kostenlos starten →