Dual‐Graded Microstructure Engineering for Flexible Piezoresistive Sensors with High Sensitivity and Broad Linear Range in Physiological Monitoring
Advanced Science · 2025-10 · 12 (38)
DOI: 10.1002/advs.202507135 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 14.07.2025. Verfasst von Ningning Bai und 11 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechano-Electronic Engineering, Xidian University, Xi'an, 710071, P. R. China. Hauptthemen laut MEDLINE: Wearable Electronic Devices. Die Arbeit wurde bisher 51-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Basic Research Program of Shaanxi Province, Postdoctoral Science Foundation of Jiangsu Province.
Abstract (Originalsprache)
Flexible piezoresistive sensors that offer both high sensitivity and a broad linear detection range are highly desirable for wearable health monitoring, as they facilitate simplified circuit design and enable accurate detection of subtle physiological signals. However, existing sensors typically encounter an intrinsic trade‐off between sensitivity and linearity, primarily due to structural stiffening under increasing pressure. Here, a flexible piezoresistive pressure sensor featuring dual‐graded microstructures (DGM) is reported, formed by embedding multi‐walled carbon nanotubes (MWCNTs) into a thermoplastic polyurethane matrix. Leveraging the synergistic effects of progressive structural deformation and MWCNTs‐induced tunneling conduction, the sensor achieves a high sensitivity of 69.8 kPa⁻¹ and a broad linear sensing range up to 300 kPa ( R 2 ≈ 0.998). The sensor also exhibits rapid response‐relaxation time (totaling 5 ms), stable high‐frequency detection up to 200 Hz, and good stability over 5 000 repeated loading cycles. Demonstrations in physiological monitoring confirm the sensor's capability to precisely capture detailed radial pulse waveforms, respiratory rhythms, and subtle heartbeat‐induced vibrations. Both a scalable, cost‐effective structural fabrication and good overall sensing performance establish the DGM‐based sensor as a promising candidate for advanced wearable healthcare monitoring devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mechano-Electronic Engineering, Xidian University, Xi'an, 710071, P. R. China.
- State Key Laboratory of Electromechanical Integrated Manufacturing of High-Performance Electronic Equipment, Xi'an, 710071, P. R. China.
- Xi'an Chuanglian Ultrasound Technology Co., Ltd, Xi'an, 710065, P. R. China.
- Xi'an Microelectronics Technology Institute, Xi'an, 710054, P. R. China.
ORCID-Profile: Ningning Bai
Förderung
- National Natural Science Foundation of China
- Natural Science Basic Research Program of Shaanxi Province
- Postdoctoral Science Foundation of Jiangsu Province
- Fundamental Research Funds for Central Universities of the Central South University
Zitieren
APA
Bai, N., Xu, D., Su, Z., Li, G., He, L., Chen, Y., Guo, C., Zhou, L., Qin, X., Zhang, J., Wu, D., & Wang, W. (2025). Dual‐Graded Microstructure Engineering for Flexible Piezoresistive Sensors with High Sensitivity and Broad Linear Range in Physiological Monitoring. Advanced Science, 12(38). https://doi.org/10.1002/advs.202507135
Vancouver
Bai N, Xu D, Su Z, Li G, He L, Chen Y, et al. Dual‐Graded Microstructure Engineering for Flexible Piezoresistive Sensors with High Sensitivity and Broad Linear Range in Physiological Monitoring. Advanced Science. 2025;12(38). doi:10.1002/advs.202507135
BibTeX
@article{Bai2025,
author = {Bai, Ningning and Xu, Dandan and Su, Zhuang and Li, Gangqiang and He, Lilong and Chen, Yanli and Guo, Chengxi and Zhou, Linxuan and Qin, Xianming and Zhang, Ji and Wu, Daowei and Wang, Weidong},
title = {Dual‐Graded Microstructure Engineering for Flexible Piezoresistive Sensors with High Sensitivity and Broad Linear Range in Physiological Monitoring},
journal = {Advanced Science},
year = {2025},
volume = {12},
number = {38},
doi = {10.1002/advs.202507135}
}
EUVIMED