Closed‐Loop Bioelectronic Artificial Pancreas Patch for Continuous Monitoring and Regulation of Blood Glucose in Diabetic Rats and Pigs

Yiqun Liu, Changxi Zhang, Lingyi Xu, Yuan Ma, Yuanyuan Ma, Ying Chen, Difei Lu, Le Ye, Li Yang, Yue Cui iD

Advanced Science · 2025-11 · 12 (44)

DOI: 10.1002/advs.202503536 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 16.09.2025. Verfasst von Yiqun Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Peking University, Beijing, 100871, P. R. China. Hauptthemen laut MEDLINE: Pancreas, Artificial, Blood Glucose, Diabetes Mellitus, Experimental, Blood Glucose Self-Monitoring. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 88 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key R&D Program of China, Beijing Young Scientist Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Integrated artificial pancreas devices with continuous glucose monitoring (CGM) and closed‐loop insulin delivery are crucial for diabetes management. However, design challenges remain, including miniaturization, low cost, stability, and low power consumption. Current commercial products are expensive ($3,000 to $8,000 USD), and bulky, typically exceeding 100 cm 3 . Here, a closed‐loop bioelectronic artificial pancreas patch is presented for continuous blood glucose regulation in diabetic rats and pigs. By designing transiently dissolvable microneedle arrays incorporated with microtube arrays, insulin is efficiently delivered into interstitial fluid, eliminating the need for an external long needle. Leveraging multi‐layer sensing electrodes, Ag/Ag 2 O glass‐fiber pumping electrodes, and a polyethylene‐glycol (PEG) functionalized polycarbonate membrane, the closed‐loop artificial pancreas patch demonstrates highly stable sensing and pumping with low power consumption (only 0.422 mW), enabling long‐term continuous operation to regulate blood glucose. In particular, diabetic pigs are operated on for 3 consecutive days, showing steady blood glucose control with a time in range (3.9–10.0 m m ) of ≈67.98%, comparable to a commercial closed‐loop system at ≈74.95%. The total volume of the entire system is ≈2 cm 3 , and the cost is ≈$10. This method opens up promising avenues for the development and application of wearable devices to manage diabetes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pancreas, ArtificialBlood GlucoseDiabetes Mellitus, ExperimentalBlood Glucose Self-MonitoringAnimalsRatsSwineInsulinInsulin Infusion SystemsRats, Sprague-DawleyEquipment Design

Stichwörter der Autor:innen

artificial pancreasclosed‐loopdiabetesglucose sensorinsulin pump

Substanzen

Blood GlucoseInsulin

Autor:innen und Institutionen

  • School of Materials Science and Engineering, Peking University, Beijing, 100871, P. R. China.
  • Renal Division, Peking University First Hospital, Peking University Institute of Nephrology, Key Laboratory of Renal Disease, Ministry of Health of China, Key Laboratory of Chronic Kidney Disease Prevention and Treatmen…
  • Laboratory Animal Center, Peking University First Hospital, Beijing, 100034, P. R. China.
  • Department of Endocrinology, Peking University First Hospital, Beijing, 100034, P. R. China.
  • School of Integrated Circuits, Peking University, Beijing, 100871, P. R. China.

ORCID-Profile: Yue Cui

Förderung

  • National Natural Science Foundation of China
  • National Key R&D Program of China
  • Beijing Young Scientist Program
  • Capital's Funds for Health Improvement and Research
  • State Key Laboratory of Vascular Homeostasis and Remodeling of Peking University
  • Beijing Science and Technology Planning Projec
  • National Key Research and Development Program of China

Zitieren

APA

Liu, Y., Zhang, C., Xu, L., Ma, Y., Ma, Y., Chen, Y., Lu, D., Ye, L., Yang, L., & Cui, Y. (2025). Closed‐Loop Bioelectronic Artificial Pancreas Patch for Continuous Monitoring and Regulation of Blood Glucose in Diabetic Rats and Pigs. Advanced Science, 12(44). https://doi.org/10.1002/advs.202503536

Vancouver

Liu Y, Zhang C, Xu L, Ma Y, Ma Y, Chen Y, et al. Closed‐Loop Bioelectronic Artificial Pancreas Patch for Continuous Monitoring and Regulation of Blood Glucose in Diabetic Rats and Pigs. Advanced Science. 2025;12(44). doi:10.1002/advs.202503536

BibTeX
@article{Liu2025,
  author = {Liu, Yiqun and Zhang, Changxi and Xu, Lingyi and Ma, Yuan and Ma, Yuanyuan and Chen, Ying and Lu, Difei and Ye, Le and Yang, Li and Cui, Yue},
  title = {Closed‐Loop Bioelectronic Artificial Pancreas Patch for Continuous Monitoring and Regulation of Blood Glucose in Diabetic Rats and Pigs},
  journal = {Advanced Science},
  year = {2025},
  volume = {12},
  number = {44},
  doi = {10.1002/advs.202503536}
}
Kostenlos starten →