Human Nervous System‐Based Biohybrid Robot‐On‐A‐Chip with Sensing Function for Toxicity Screening

Minkyu Shin, Joungpyo Lim, Seewoo Kim, Sangeun Lee, Wei Wen Su, Jinho Yoon, Jeong-Woo Choi iD

Advanced Science · 2025-10 · 12 (37)

DOI: 10.1002/advs.202501452 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 02.07.2025. Verfasst von Minkyu Shin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical & Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul, 04107, Republic of Korea. Hauptthemen laut MEDLINE: Robotics, Lab-On-A-Chip Devices, Toxicity Tests. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea, Ministry of Science and ICT, Ministry of Science and ICT, South Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biohybrid robots and biohybrid robot‐on‐a‐chip have been developed for drug screening and toxicity screening the complementing animal experiments. A sensing system is needed to evaluate the response to external stimulation, but until now, only the human motor system‐based biohybrid robot‐on‐a‐chip with neuromuscular system has been developed without a sensing system. A human nervous system‐based biohybrid robot‐on‐a‐chip with eye function as a sensing system in addition to brain/motor neuron/muscle functions is proposed for the first time. Eye assembloid is fabricated by a combination of thalamic organoid covered with Au nanomesh and four retinal organoids. By a combination of eye assembloid, cerebral organoid, motor neuron spheroid, and muscle bundle on polymer substrate, a human nervous system‐based biohybrid robot‐on‐a‐chip is made. When blue light is used to cause retinal damage or a hydroxychloroquine (HCQ), a retinal toxic chemical, is applied to the eye assembloid, they caused a decrease in muscle bundle contraction. These results indicated that electrophysiological signals generated by the eye assembloid are transmitted to the muscle bundle through cerebral organoid and motor neuron spheroids, and thus the proposed system can perform the toxicity screening. Human nervous system‐based biohybrid robot‐on‐a‐chip can be applied to drug screening of neurodegenerative diseases and toxicity screening for the complement of animal experiments in the future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RoboticsLab-On-A-Chip DevicesToxicity TestsHumansAnimalsMotor Neurons

Stichwörter der Autor:innen

Biohybrid robot‐on‐a‐chipBrain organoidEye assembloidHuman nervous systemMotor neuron spheroidsMuscle bundleToxicity screening

Autor:innen und Institutionen

  • Department of Chemical & Biomolecular Engineering, Sogang University, 35 Baekbeom-ro, Mapo-gu, Seoul, 04107, Republic of Korea.
  • Department of Molecular Biosciences and Bioengineering, University of Hawaii at Manoa, Honolulu, HI 96822, USA.
  • Department of Biomedical-Chemical Engineering, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do, 14662, Republic of Korea.

ORCID-Profile: Jeong-Woo Choi

Förderung

  • National Research Foundation of Korea
  • Ministry of Science and ICT
  • Ministry of Science and ICT, South Korea

Zitieren

APA

Shin, M., Lim, J., Kim, S., Lee, S., Su, W. W., Yoon, J., & Choi, J. W. (2025). Human Nervous System‐Based Biohybrid Robot‐On‐A‐Chip with Sensing Function for Toxicity Screening. Advanced Science, 12(37). https://doi.org/10.1002/advs.202501452

Vancouver

Shin M, Lim J, Kim S, Lee S, Su WW, Yoon J, et al. Human Nervous System‐Based Biohybrid Robot‐On‐A‐Chip with Sensing Function for Toxicity Screening. Advanced Science. 2025;12(37). doi:10.1002/advs.202501452

BibTeX
@article{Shin2025,
  author = {Shin, Minkyu and Lim, Joungpyo and Kim, Seewoo and Lee, Sangeun and Su, Wei Wen and Yoon, Jinho and Choi, Jeong-Woo},
  title = {Human Nervous System‐Based Biohybrid Robot‐On‐A‐Chip with Sensing Function for Toxicity Screening},
  journal = {Advanced Science},
  year = {2025},
  volume = {12},
  number = {37},
  doi = {10.1002/advs.202501452}
}
Kostenlos starten →