A Bias‐Tunable Multispectral Photodetector Based on a GaN/Te x Se 1‐ x Homo‐Type Heterojunction with a Unidirectional Barrier
Advanced Science · 2025-05 · 12 (17)
DOI: 10.1002/advs.202417428 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 07.03.2025. Verfasst von Weijie Liu und 14 weiteren Autor:innen. Beteiligte Einrichtung: Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430074, China. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Multispectral detection technology captures characteristic spectral information across various wavebands, exhibiting substantial application potential. However, most currently reported multispectral photodetectors rely on intricate dual‐ or multi‐junction structures, severely limiting material thickness, doping concentration, and band alignment design, thereby impeding widespread adoption. In this study, a bias‐tunable multispectral photodetector featuring a straightforward single‐junction design is introduced. The device comprises a Te x Se 1‐ x /GaN homo‐type heterojunction with a unidirectional barrier. This structure effectively suppresses the majority‐carrier dark current, yielding a low reverse dark current of ≈10 −12 A and a high rectification ratio of up to 10 5 . By adjusting the bias polarity and magnitude, the spectral response range of the device can be broadened from ultraviolet (UV) to short‐wave infrared. Notably, the photodetection performance is exceptional: at 0 V bias, the device exhibits a responsivity of 0.25 A W −1 and a specific detectivity of 5.04 × 10 11 cm Hz 1/2 W −1 under 365 nm illumination; at −2 V bias, it achieves a responsivity of 0.58 A W −1 and a specific detectivity of 2.64 × 10 9 cm Hz 1/2 W −1 under 1060 nm illumination. Leveraging the bias‐tunable spectral response characteristic of the device, proof‐of‐concept imaging is successfully demonstrated. This research presents a simplified and economical method for fabricating multispectral photodetectors.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430074, China.
- State Key Laboratory of Infrared Science and Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, 200083, China.
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan, 430074, China.
ORCID-Profile: Feng Wu
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
Zitieren
APA
Liu, W., Peng, M., Chen, M., Zhao, Y., Yu, Y., Jian, P., Liu, Z., Zeng, Y., Luo, Y., Tian, X., Gao, Z., Dai, J., Chen, C., Wu, F., & Hu, W. (2025). A Bias‐Tunable Multispectral Photodetector Based on a GaN/Te x Se 1‐ x Homo‐Type Heterojunction with a Unidirectional Barrier. Advanced Science, 12(17). https://doi.org/10.1002/advs.202417428
Vancouver
Liu W, Peng M, Chen M, Zhao Y, Yu Y, Jian P, et al. A Bias‐Tunable Multispectral Photodetector Based on a GaN/Te x Se 1‐ x Homo‐Type Heterojunction with a Unidirectional Barrier. Advanced Science. 2025;12(17). doi:10.1002/advs.202417428
BibTeX
@article{Liu2025,
author = {Liu, Weijie and Peng, Meng and Chen, Maohua and Zhao, Yongming and Yu, Yiye and Jian, Pengcheng and Liu, Zunyu and Zeng, Yuhui and Luo, Yuang and Tian, Xiantai and Gao, Zhiwei and Dai, Jiangnan and Chen, Changqing and Wu, Feng and Hu, Weida},
title = {A Bias‐Tunable Multispectral Photodetector Based on a GaN/Te x Se 1‐ x Homo‐Type Heterojunction with a Unidirectional Barrier},
journal = {Advanced Science},
year = {2025},
volume = {12},
number = {17},
doi = {10.1002/advs.202417428}
}
EUVIMED