EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Advancements in Bio‐Integrated Flexible Electronics for Hemodynamic Monitoring in Cardiovascular Healthcare

Ke Huang iD, Zhiqiang Ma iD, Bee Luan Khoo iD

Advanced Science · 2025-07 · 12 (25)

DOI: 10.1002/advs.202415215 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Advanced Science, online erschienen am 25.04.2025. Verfasst von Ke Huang und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, China. Hauptthemen laut MEDLINE: Cardiovascular Diseases, Hemodynamic Monitoring, Hemodynamics, Electronics. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 236 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: City University of Hong Kong, Research Grants Council, Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Innovation and Technology Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiovascular diseases (CVDs) remain the leading cause of global mortality, highlighting the urgent need for effective monitoring and prevention strategies. The rapid advancement of flexible sensing technology and the development of conformal sensors have attracted significant attention due to their potential for continuous, real‐time assessment of cardiovascular health over extended periods. This review outlines recent advancements in bio‐integrated flexible electronics designed for hemodynamic monitoring and broader CVD healthcare applications. It introduces key physiological indicators relevant to hemodynamics, including heart rate, blood pressure, blood flow velocity, and cardiac output. Next, it discusses flexible bio‐integrated electronics engineering strategies, such as working principles and configuration designs. Various non‐invasive and invasive bio‐integrated devices for monitoring these hemodynamic indicators are then presented. Additionally, the review highlights the role of artificial intelligence algorithms and their practical applications in bio‐integrated electronics for hemodynamic detection. Finally, it proposes future directions and addresses potential challenges in the field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiovascular DiseasesHemodynamic MonitoringHemodynamicsElectronicsHumansMonitoring, Physiologic

Stichwörter der Autor:innen

artificial intelligencebio‐integrated electronicscardiovascular diseasesflexible conformal sensorshemodynamic monitoring

Autor:innen und Institutionen

  • Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, 999077, China.
  • Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Hong Kong, 999077, China.
  • Department of Precision Diagnostic and Therapeutic Technology, City University of Hong Kong Shenzhen-Futian Research Institute, Shenzhen, 518057, China.

ORCID-Profile: Ke Huang, Zhiqiang Ma, Bee Luan Khoo

Förderung

  • City University of Hong Kong
  • Research Grants Council
  • Hong Kong Center for Cerebro-Cardiovascular Health Engineering (COCHE), Innovation and Technology Commission
  • Hetao Shenzhen-Hong Kong Science and Technology Innovation Cooperation Zone Shenzhen Park Project
  • Education Bureau Gifted Education Programme

Zitieren

APA

Huang, K., Ma, Z., & Khoo, B. L. (2025). Advancements in Bio‐Integrated Flexible Electronics for Hemodynamic Monitoring in Cardiovascular Healthcare. Advanced Science, 12(25). https://doi.org/10.1002/advs.202415215

Vancouver

Huang K, Ma Z, Khoo BL. Advancements in Bio‐Integrated Flexible Electronics for Hemodynamic Monitoring in Cardiovascular Healthcare. Advanced Science. 2025;12(25). doi:10.1002/advs.202415215

BibTeX
@article{Huang2025,
  author = {Huang, Ke and Ma, Zhiqiang and Khoo, Bee Luan},
  title = {Advancements in Bio‐Integrated Flexible Electronics for Hemodynamic Monitoring in Cardiovascular Healthcare},
  journal = {Advanced Science},
  year = {2025},
  volume = {12},
  number = {25},
  doi = {10.1002/advs.202415215}
}
Kostenlos starten →