Fachartikel in der Zeitschrift Advanced Science, online erschienen am 17.02.2025. Verfasst von Woo Hyun Kim und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biological Engineering, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Sepsis, Machine Learning, Spectrum Analysis, Raman. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ansan Hospital and College of Engineering, Korea University, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and accurate differential diagnosis of infections, sepsis, and septic shock is essential for preventing unnecessary antibiotic overuse and improving the chance of patient survival. To address this, a 3D gold nanogranule decorated gold‐silver alloy nanopillar (AuNG@Au‐AgNP) based surface‐enhanced Raman scattering (SERS) biosensor is developed, capable of quantitatively profiling immune‐related soluble proteins (interleukin three receptor, alpha chain: CD123, programmed cell death ligand 1: PD‐L1, human leukocyte antigen–DR isotype: HLA‐DR, and chitotriosidase: ChiT) in serum samples. The 3D bimetallic nanoarchitecture, fabricated using anodized aluminum oxide (AAO), features a uniform structure with densely packed nanogaps on the heads of Au‐Ag alloy nanopillars, enabling fast, simple, and replicable production. The proposed biosensor achieves accurate results even with low detection limits (4–6 fM) and high signal consistency (relative standard deviation (RSD) = 1.79%) within a one‐step multi‐analytes identification chip with a directly loadable chamber. To enhance the diagnostic performance, a support vector machine (SVM) based machine learning algorithm is utilized, achieving 95.0% accuracy and 95.8% precision in classifying healthy controls, infections with and without sepsis, and septic shock. This advanced 3D plasmonic bimetallic alloy nanoarchitecture‐based SERS biosensor demonstrates clinical usefulness for sepsis diagnosis and severity assessment, providing timely and personalized treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesSepsisMachine LearningSpectrum Analysis, RamanHumansDiagnosis, DifferentialGoldAlloysMetal NanoparticlesSilver

Stichwörter der Autor:innen

3D bimetallic alloy nanoarchitectureall‐in‐one multiplex detectiondifferential diagnosis of sepsissoluble proteinsurface‐enhanced Raman scattering (SERS)

Substanzen

GoldAlloysSilver

Autor:innen und Institutionen

  • Department of Chemical and Biological Engineering, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea.
  • Institute of Basic Science, Sungkyunkwan University, Suwon, 16419, Republic of Korea.
  • Department of Emergency Medicine Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Republic of Korea.
  • Division of Infectious Diseases, Department of Internal Medicine, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Republic of Korea.
  • Department of Chemistry, Yonsei University, Seoul, 03722, Republic of Korea.

ORCID-Profile: Sungho Park, Sang Jun Sim

Förderung

  • Ansan Hospital and College of Engineering
  • Korea University
  • National Research Foundation of Korea
  • Korean government
  • Korea Dementia Research Project through the Korea Dementia Research Center
  • Ministry of Health & Welfare and the Ministry of Science and ICT

Zitieren

APA

Kim, W. H., Lee, S., Jeon, M. J., Lee, K. J., Park, J. H., Park, D. W., Park, S., & Sim, S. J. (2025). Rapid and Differential Diagnosis of Sepsis Stages Using an Advanced 3D Plasmonic Bimetallic Alloy Nanoarchitecture‐Based SERS Biosensor Combined with Machine Learning for Multiple Analyte Identification. Advanced Science, 12(14). https://doi.org/10.1002/advs.202414688

Vancouver

Kim WH, Lee S, Jeon MJ, Lee KJ, Park JH, Park DW, et al. Rapid and Differential Diagnosis of Sepsis Stages Using an Advanced 3D Plasmonic Bimetallic Alloy Nanoarchitecture‐Based SERS Biosensor Combined with Machine Learning for Multiple Analyte Identification. Advanced Science. 2025;12(14). doi:10.1002/advs.202414688

BibTeX
@article{Kim2025,
  author = {Kim, Woo Hyun and Lee, Sungwoo and Jeon, Myeong Jin and Lee, Kwon Jun and Park, Jong-Hak and Park, Dae Won and Park, Sungho and Sim, Sang Jun},
  title = {Rapid and Differential Diagnosis of Sepsis Stages Using an Advanced 3D Plasmonic Bimetallic Alloy Nanoarchitecture‐Based SERS Biosensor Combined with Machine Learning for Multiple Analyte Identification},
  journal = {Advanced Science},
  year = {2025},
  volume = {12},
  number = {14},
  doi = {10.1002/advs.202414688}
}
Kostenlos starten →