Fundamentals and Implication of Point of Zero Charge (PZC) Determination for Activated Carbons in Aqueous Electrolytes
Advanced Science · 2024-12 · 11 (48)
DOI: 10.1002/advs.202409162 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 13.11.2024. Verfasst von Sylwia Slesinska und 5 weiteren Autor:innen. Beteiligte Einrichtung: Poznan University of Technology, Institute of Chemistry and Technical Electrochemistry, Berdychowo 4, Poznan, 60965, Poland. Die Arbeit wurde bisher 26-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council (ERC) Starting Grant, NCN, European Research Council (ERC) Proof of Concept.
Abstract (Originalsprache)
The point of zero charge (PZC) is a crucial parameter for investigating the charge storage mechanisms in energy storage systems at the molecular level. This paper presents findings from three different electrochemical techniques, compared for the first time: cyclic voltammetry (CV), staircase potentio electrochemical impedance spectroscopy (SPEIS), and step potential electrochemical spectroscopy (SPECS), for two activated carbons (ACs) with 0.1 mol L −1 aqueous solution of LiNO 3 , Li 2 SO 4 , and KI. The charging process of AC operating in aqueous electrolytes appears as a complex phenomenon – all ionic species take an active part in electric double‐layer formation and the ion‐mixing zone covers a wide potential region. Therefore, the so‐called PZC should not be considered as an absolute one‐point potential value, but rather as a range of zero charge (RZC). SPECS technique is found to be a universal and fast method for determining RZC, as applied here together with the EQCM. In most cases, the RZC covers a potential range from ≈100 to ≈200 mV and the correlation of the range with the carbon microtexture is clear, highlighting the role of the ion‐sieving effect. It is postulated that PZC for porous materials in aqueous electrolytic solutions should be considered instead as RZC.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Poznan University of Technology, Institute of Chemistry and Technical Electrochemistry, Berdychowo 4, Poznan, 60965, Poland.
- Discipline of Chemistry, University of Newcastle, Callaghan, New South Wales, 2308, Australia.
- Laboratory for Multiphase Thermofluidics and Surface Nanoengineering, Department of Mechanical and Process Engineering, ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland.
- Unbound Potential GmbH, Bönirainstrasse 14, Thalwil, 8800, Switzerland.
ORCID-Profile: Sylwia Slesinska, Przemysław Galek, Jakub Menzel, Scott W Donne, Krzysztof Fic, Anetta Płatek-Mielczarek
Förderung
- European Research Council (ERC) Starting Grant
- NCN
- European Research Council (ERC) Proof of Concept
- Narodowe Centrum Nauki
Zitieren
APA
Slesinska, S., Galek, P., Menzel, J., Donne, S. W., Fic, K., & Płatek-Mielczarek, A. (2024). Fundamentals and Implication of Point of Zero Charge (PZC) Determination for Activated Carbons in Aqueous Electrolytes. Advanced Science, 11(48). https://doi.org/10.1002/advs.202409162
Vancouver
Slesinska S, Galek P, Menzel J, Donne SW, Fic K, Płatek-Mielczarek A. Fundamentals and Implication of Point of Zero Charge (PZC) Determination for Activated Carbons in Aqueous Electrolytes. Advanced Science. 2024;11(48). doi:10.1002/advs.202409162
BibTeX
@article{Slesinska2024,
author = {Slesinska, Sylwia and Galek, Przemysław and Menzel, Jakub and Donne, Scott W and Fic, Krzysztof and Płatek-Mielczarek, Anetta},
title = {Fundamentals and Implication of Point of Zero Charge (PZC) Determination for Activated Carbons in Aqueous Electrolytes},
journal = {Advanced Science},
year = {2024},
volume = {11},
number = {48},
doi = {10.1002/advs.202409162}
}
EUVIMED