Bioinspired Suspended Sensing Membrane Array with Modulable Wedged‐Conductive Channels for Crosstalk‐Free and High‐Resolution Detection
Advanced Science · 2024-07 · 11 (28)
DOI: 10.1002/advs.202403645 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 08.05.2024. Verfasst von Haixuan Luo und 11 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China. Hauptthemen laut MEDLINE: Equipment Design. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Joint Fund of Ministry of Education for Equipment Pre-research, Aeronautical Science Foundation of China.
Abstract (Originalsprache)
High spatial‐resolution detection is essential for biomedical applications and human‐machine interaction. However, as the sensor array density increases, the miniaturization will lead to interference between adjacent units and deterioration in sensing performance. Here, inspired by the cochlea's sensing structure, a high‐density flexible pressure sensor array featuring with suspended sensing membrane with sensitivity‐enhanced customized channels is presented for crosstalk‐free and high‐resolution detection. By imitating the basilar membrane attached to spiral ligaments, a sensing membrane is fixed onto a high‐stiffness substrate with cavities, forming a stable braced isolation to provide an excellent crosstalk‐free capability (crosstalk coefficient: 47.24 dB) with high‐density integration (100 units within 1 cm 2 ). Similar to the opening of ion channels in hair cells, the wedge‐type expansion of the embedded cracks introduced by stress concentration structures enables a high sensitivity (0.19 kPa −1 ) and a large measuring range (400 kPa). Finally, it demonstrates promising applications in distributed displays and the condition monitoring of medical‐surgical intubation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.
- Frontier Institute of Science and Technology (FIST), Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.
- Department of Rehabilitation, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, China.
ORCID-Profile: Xiaoliang Chen, Jinyou Shao
Förderung
- National Natural Science Foundation of China
- Joint Fund of Ministry of Education for Equipment Pre-research
- Aeronautical Science Foundation of China
Zitieren
APA
Luo, H., Chen, X., Li, S., Xu, J., Li, X., Tian, H., Wang, C., Li, B., Zhang, M., Sun, B., He, J., & Shao, J. (2024). Bioinspired Suspended Sensing Membrane Array with Modulable Wedged‐Conductive Channels for Crosstalk‐Free and High‐Resolution Detection. Advanced Science, 11(28). https://doi.org/10.1002/advs.202403645
Vancouver
Luo H, Chen X, Li S, Xu J, Li X, Tian H, et al. Bioinspired Suspended Sensing Membrane Array with Modulable Wedged‐Conductive Channels for Crosstalk‐Free and High‐Resolution Detection. Advanced Science. 2024;11(28). doi:10.1002/advs.202403645
BibTeX
@article{Luo2024,
author = {Luo, Haixuan and Chen, Xiaoliang and Li, Sheng and Xu, Jinbin and Li, Xiangming and Tian, Hongmiao and Wang, Chunhui and Li, Bo and Zhang, Manman and Sun, Bai and He, Juan and Shao, Jinyou},
title = {Bioinspired Suspended Sensing Membrane Array with Modulable Wedged‐Conductive Channels for Crosstalk‐Free and High‐Resolution Detection},
journal = {Advanced Science},
year = {2024},
volume = {11},
number = {28},
doi = {10.1002/advs.202403645}
}
EUVIMED