Cutaneous Electrohydraulic (CUTE) Wearable Devices for Pleasant Broad‐Bandwidth Haptic Cues
Advanced Science · 2024-12 · 11 (48)
DOI: 10.1002/advs.202402461 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 06.09.2024. Verfasst von Natalia Sanchez-Tamayo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Haptic Intelligence Department, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Cues, Equipment Design. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 90 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: International Max Planck Research School for Intelligent Systems, Max-Planck-Gesellschaft.
Abstract (Originalsprache)
By focusing on vibrations, current wearable haptic devices underutilize the skin's perceptual capabilities. Devices that provide richer haptic stimuli, including contact feedback and/or variable pressure, are typically heavy and bulky due to the underlying actuator technology and the low sensitivity of hairy skin, which covers most of the body. This article presents a system architecture for compact wearable devices that deliver salient and pleasant broad‐bandwidth haptic cues: Cutaneous Electrohydraulic (CUTE) devices combine a custom materials design for soft haptic electrohydraulic actuators that feature high stroke, high force, and electrical safety with a comfortable mounting strategy that places the actuator in a non‐contact resting position. A prototypical wrist‐wearable CUTE device produces rich tactile sensations by making and breaking contact with the skin (2.44 mm actuation stroke), applying high controllable forces (exceeding 2.3 N), and delivering vibrations at a wide range of amplitudes and frequencies (0–200 Hz). A perceptual study with 14 participants achieves 97.9% recognition accuracy across six diverse cues and verifies their pleasant and expressive feel. This system architecture for wearable devices gives unprecedented control over the haptic cues delivered to the skin, providing an elegant and discreet way to activate the user's sense of touch.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Haptic Intelligence Department, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
- Robotic Materials Department, Max Planck Institute for Intelligent Systems, Heisenbergstr. 3, 70569, Stuttgart, Germany.
- Institute for Control Engineering of Machine Tools and Manufacturing Units, University of Stuttgart, Seidenstraße 36, 70174, Stuttgart, Germany.
- Paul M. Rady Department of Mechanical Engineering, University of Colorado, Boulder, 1111 Engineering Drive, Boulder, CO, 80309, USA.
- Materials Science and Engineering Program, University of Colorado, Boulder, 1111 Engineering Drive, Boulder, CO, 80309, USA.
ORCID-Profile: Natalia Sanchez-Tamayo, Zachary Yoder, Philipp Rothemund, Giulia Ballardini, Christoph Keplinger, Katherine J Kuchenbecker
Förderung
- International Max Planck Research School for Intelligent Systems
- Max-Planck-Gesellschaft
Zitieren
APA
Sanchez-Tamayo, N., Yoder, Z., Rothemund, P., Ballardini, G., Keplinger, C., & Kuchenbecker, K. J. (2024). Cutaneous Electrohydraulic (CUTE) Wearable Devices for Pleasant Broad‐Bandwidth Haptic Cues. Advanced Science, 11(48). https://doi.org/10.1002/advs.202402461
Vancouver
Sanchez-Tamayo N, Yoder Z, Rothemund P, Ballardini G, Keplinger C, Kuchenbecker KJ. Cutaneous Electrohydraulic (CUTE) Wearable Devices for Pleasant Broad‐Bandwidth Haptic Cues. Advanced Science. 2024;11(48). doi:10.1002/advs.202402461
BibTeX
@article{SanchezTamayo2024,
author = {Sanchez-Tamayo, Natalia and Yoder, Zachary and Rothemund, Philipp and Ballardini, Giulia and Keplinger, Christoph and Kuchenbecker, Katherine J},
title = {Cutaneous Electrohydraulic (CUTE) Wearable Devices for Pleasant Broad‐Bandwidth Haptic Cues},
journal = {Advanced Science},
year = {2024},
volume = {11},
number = {48},
doi = {10.1002/advs.202402461}
}
EUVIMED