EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Early Detection and Monitoring of Anastomotic Leaks via Naked Eye‐Readable, Non‐Electronic Macromolecular Network Sensors

Alexander Jessernig, Alexandre H C Anthis, Emilie Vonna, Jachym Rosendorf, Vaclav Liska, Jeannette Widmer, Andrea A Schlegel, Inge K Herrmann iD

Advanced Science · 2024-08 · 11 (29)

DOI: 10.1002/advs.202400673 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Science, online erschienen am 22.05.2024. Verfasst von Alexander Jessernig und 7 weiteren Autor:innen. Beteiligte Einrichtung: Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-…. Hauptthemen laut MEDLINE: Anastomotic Leak, Early Diagnosis. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ETH Domain Specific Focus Area Personalized Health and Related Technologies (PHRT) program, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Anastomotic leakage (AL) is the leaking of non‐sterile gastrointestinal contents into a patient's abdominal cavity. AL is one of the most dreaded complications following gastrointestinal surgery, with mortality rates reaching up to 27%. The current diagnostic methods for anastomotic leaks are limited in sensitivity and specificity. Since the timing of detection directly impacts patient outcomes, developing new, fast, and simple methods for early leak detection is crucial. Here, a naked eye‐readable, electronic‐free macromolecular network drain fluid sensor is introduced for continuous monitoring and early detection of AL at the patient's bedside. The sensor array comprises three different macromolecular network sensing elements, each tailored for selectivity toward the three major digestive enzymes found in the drainage fluid during a developing AL. Upon digestion of the macromolecular network structure by the respective digestive enzymes, the sensor produces an optical shift discernible to the naked eye. The diagnostic efficacy and clinical applicability of these sensors are demonstrated using clinical samples from 32 patients, yielding a Receiver Operating Characteristic Area Under the Curve (ROC AUC) of 1.0. This work has the potential to significantly contribute to improved patient outcomes through continuous monitoring and early, low‐cost, and reliable AL detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anastomotic LeakEarly DiagnosisHumansBiosensing Techniques

Stichwörter der Autor:innen

devicedrain fluidpostoperative complicationssensingwearables

Autor:innen und Institutionen

  • Nanoparticle Systems Engineering Laboratory, Institute of Energy and Process Engineering (IEPE), Department of Mechanical and Process Engineering (D-MAVT), ETH Zurich, Sonneggstrasse 3, Zurich, 8092, Switzerland.
  • Particles-Biology Interactions Laboratory, Department of Materials Meet Life, Swiss Federal Laboratories for Materials Science and Technology (Empa), Lerchenfeldstrasse 5, St. Gallen, 9014, Switzerland.
  • Department of Surgery, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 923/80, Pilsen, 32300, Czech Republic.
  • Biomedical Center, Faculty of Medicine in Pilsen, Charles University, Alej Svobody 1655/76, Pilsen, 32300, Czech Republic.
  • Department of Surgery and Transplantation, Swiss HPB Centre, University Hospital Zurich, Zürich, 8091, Switzerland.
  • Transplantation Center, Digestive Disease and Surgery Institute and Department of Immunity and Inflammation, Lerner Research Institute, Cleveland Clinic, 9620 Carnegie Ave, Cleveland, OH, 44106, USA.

ORCID-Profile: Inge K Herrmann

Förderung

  • ETH Domain Specific Focus Area Personalized Health and Related Technologies (PHRT) program
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Zitieren

APA

Jessernig, A., Anthis, A. H. C., Vonna, E., Rosendorf, J., Liska, V., Widmer, J., Schlegel, A. A., & Herrmann, I. K. (2024). Early Detection and Monitoring of Anastomotic Leaks via Naked Eye‐Readable, Non‐Electronic Macromolecular Network Sensors. Advanced Science, 11(29). https://doi.org/10.1002/advs.202400673

Vancouver

Jessernig A, Anthis AHC, Vonna E, Rosendorf J, Liska V, Widmer J, et al. Early Detection and Monitoring of Anastomotic Leaks via Naked Eye‐Readable, Non‐Electronic Macromolecular Network Sensors. Advanced Science. 2024;11(29). doi:10.1002/advs.202400673

BibTeX
@article{Jessernig2024,
  author = {Jessernig, Alexander and Anthis, Alexandre H C and Vonna, Emilie and Rosendorf, Jachym and Liska, Vaclav and Widmer, Jeannette and Schlegel, Andrea A and Herrmann, Inge K},
  title = {Early Detection and Monitoring of Anastomotic Leaks via Naked Eye‐Readable, Non‐Electronic Macromolecular Network Sensors},
  journal = {Advanced Science},
  year = {2024},
  volume = {11},
  number = {29},
  doi = {10.1002/advs.202400673}
}