Palm‐Sized Lab‐In‐A‐Magnetofluidic Tube Platform for Rapid and Sensitive Virus Detection
Advanced Science · 2024-06 · 11 (23)
DOI: 10.1002/advs.202310066 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 17.04.2024. Verfasst von Ziyue Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, Connecticut, 06030, USA. Hauptthemen laut MEDLINE: SARS-CoV-2, Nucleic Acid Amplification Techniques, COVID-19, Lab-On-A-Chip Devices. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NIBIB NIH HHS, NIOSH CDC HHS.
Abstract (Originalsprache)
Simple, sensitive, and accurate molecular diagnostics are critical for preventing rapid spread of infection and initiating early treatment of diseases. However, current molecular detection methods typically rely on extensive nucleic acid sample preparation and expensive instrumentation. Here, a simple, fully integrated, lab‐in‐a‐magnetofluidic tube (LIAMT) platform is presented for “sample‐to‐result” molecular detection of virus. By leveraging magnetofluidic transport of micro/nano magnetic beads, the LIAMT device integrates viral lysis, nucleic acid extraction, isothermal amplification, and CRISPR detection within a single engineered microcentrifuge tube. To enable point‐of‐care molecular diagnostics, a palm‐sized processor is developed for magnetofluidic separation, nucleic acid amplification, and visual fluorescence detection. The LIAMT platform is applied to detect SARS‐CoV‐2 and HIV viruses, achieving a detection sensitivity of 73.4 and 63.9 copies µL −1 , respectively. Its clinical utility is further demonstrated by detecting SARS‐CoV‐2 and HIV in clinical samples. This simple, affordable, and portable LIAMT platform holds promise for rapid and sensitive molecular diagnostics of infectious diseases at the point‐of‐care.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, Connecticut, 06030, USA.
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut, 06269, USA.
- Department of Pathology and Laboratory Medicine, University of Connecticut Health Center, Farmington, Connecticut, 06030, USA.
- Department of Medicine, Division of Infectious Diseases, University of Connecticut Health Center, Farmington, Connecticut, 06030, USA.
- Department of Mechanical Engineering, University of Nevada, Las Vegas, Nevada, 89154, USA.
ORCID-Profile: Changchun Liu
Förderung
- NIH HHS
- NIBIB NIH HHS
- NIOSH CDC HHS
- NIAID NIH HHS
- National Institutes of Health
Zitieren
APA
Li, Z., Zhang, S., Zhang, J., Avery, L., Banach, D., Zhao, H., & Liu, C. (2024). Palm‐Sized Lab‐In‐A‐Magnetofluidic Tube Platform for Rapid and Sensitive Virus Detection. Advanced Science, 11(23). https://doi.org/10.1002/advs.202310066
Vancouver
Li Z, Zhang S, Zhang J, Avery L, Banach D, Zhao H, et al. Palm‐Sized Lab‐In‐A‐Magnetofluidic Tube Platform for Rapid and Sensitive Virus Detection. Advanced Science. 2024;11(23). doi:10.1002/advs.202310066
BibTeX
@article{Li2024,
author = {Li, Ziyue and Zhang, Shuo and Zhang, Jiongyu and Avery, Lori and Banach, David and Zhao, Hui and Liu, Changchun},
title = {Palm‐Sized Lab‐In‐A‐Magnetofluidic Tube Platform for Rapid and Sensitive Virus Detection},
journal = {Advanced Science},
year = {2024},
volume = {11},
number = {23},
doi = {10.1002/advs.202310066}
}
EUVIMED