High Spatiotemporal Resolution Radial Encoding Single‐Vessel fMRI
Advanced Science · 2024-07 · 11 (26)
DOI: 10.1002/advs.202309218 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 30.04.2024. Verfasst von Yuanyuan Jiang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, 02129, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, NIH HHS, NIMH NIH HHS.
Abstract (Originalsprache)
High‐field preclinical functional MRI (fMRI) is enabled the high spatial resolution mapping of vessel‐specific hemodynamic responses, that is single‐vessel fMRI. In contrast to investigating the neuronal sources of the fMRI signal, single‐vessel fMRI focuses on elucidating its vascular origin, which can be readily implemented to identify vascular changes relevant to vascular dementia or cognitive impairment. However, the limited spatial and temporal resolution of fMRI is hindered hemodynamic mapping of intracortical microvessels. Here, the radial encoding MRI scheme is implemented to measure BOLD signals of individual vessels penetrating the rat somatosensory cortex. Radial encoding MRI is employed to map cortical activation with a focal field of view (FOV), allowing vessel‐specific functional mapping with 50 × 50 µm 2 in‐plane resolution at a 1 to 2 Hz sampling rate. Besides detecting refined hemodynamic responses of intracortical micro‐venules, the radial encoding‐based single‐vessel fMRI enables the distinction of fMRI signals from vessel and peri‐vessel voxels due to the different contribution of intravascular and extravascular effects.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital and Harvard Medical School, Charlestown, MA, 02129, USA.
- Institute of Neuroscience and Medicine 4, Medical Imaging Physics, Forschungszentrum Jülich, 52425, Jülich, Germany.
- High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany.
ORCID-Profile: Yuanyuan Jiang, Xin Yu
Förderung
- NINDS NIH HHS
- NIH HHS
- NIMH NIH HHS
- National Institutes of Health
- National Science Foundation
Zitieren
APA
Jiang, Y., Pais-Roldán, P., Pohmann, R., & Yu, X. (2024). High Spatiotemporal Resolution Radial Encoding Single‐Vessel fMRI. Advanced Science, 11(26). https://doi.org/10.1002/advs.202309218
Vancouver
Jiang Y, Pais-Roldán P, Pohmann R, Yu X. High Spatiotemporal Resolution Radial Encoding Single‐Vessel fMRI. Advanced Science. 2024;11(26). doi:10.1002/advs.202309218
BibTeX
@article{Jiang2024,
author = {Jiang, Yuanyuan and Pais-Roldán, Patricia and Pohmann, Rolf and Yu, Xin},
title = {High Spatiotemporal Resolution Radial Encoding Single‐Vessel fMRI},
journal = {Advanced Science},
year = {2024},
volume = {11},
number = {26},
doi = {10.1002/advs.202309218}
}
EUVIMED