An Alternating Current Electroosmotic Flow‐Based Ultrasensitive Electrochemiluminescence Microfluidic System for Ultrafast Monitoring, Detection of Proteins/miRNAs in Unprocessed Samples
Advanced Science · 2024
DOI: 10.1002/advs.202307840 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, 2024. Verfasst von Huiwen Xiong und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Fudan University, Shanghai, 200438, P. R. China. Hauptthemen laut MEDLINE: MicroRNAs, Metal Nanoparticles. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Shanghai Scientific and Technological Innovation Action Plan.
Abstract (Originalsprache)
Early diagnosis of acute diseases is restricted by the sensitivity and complex process of sample treatment. Here, an ultrasensitive, rapid, and portable electrochemiluminescence‐microfluidic (ECL‐M) system is described via sandwich‐type immunoassay and surface plasmonic resonance (SPR) assay. Using a sandwich immunoreaction approach, the ECL‐M system employs cardiac troponin‐I antigen (cTnI) as a detection model with a Ru@SiO 2 NPs labeled antibody as the signal probe. For miR‐499‐5p detection, gold nanoparticles generate SPR effects to enhance Ru(bpy) 3 2+ ECL signals. The system based on alternating current (AC) electroosmotic flow achieves an LOD of 2 fg mL −1 for cTnI in 5 min and 10 aM for miRNAs in 10 min at room temperature. The point‐of‐care testing (POCT) device demonstrated 100% sensitivity and 98% specificity for cTnI detection in 123 clinical serum samples. For miR‐499‐5p, it exhibited 100% sensitivity and 97% specificity in 55 clinical serum samples. Continuous monitoring of these biomarkers in rats' saliva, urine, and interstitial fluid samples for 48 hours revealed observations rarely documented in biotic fluids. The ECL‐M POCT device stands as a top‐performing system for ECL analysis, offering immense potential for ultrasensitive, rapid, highly accurate, and facile detection and monitoring of acute diseases in POC settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Fudan University, Shanghai, 200438, P. R. China.
- Institutes of Biomedical Sciences and Minhang Hospital, Fudan University, Shanghai, 200032, P. R. China.
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, Fudan University, Shanghai, 200438, P. R. China.
- Department of Laboratory Medicine, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, 710061, P. R. China.
- Yizheng Hospital of Traditional Chinese Medicine, Yangzhou, 211400, P. R. China.
ORCID-Profile: Xueen Fang
Förderung
- National Natural Science Foundation of China
- Shanghai Scientific and Technological Innovation Action Plan
Zitieren
APA
Xiong, H., Zhu, C., Dai, C., Ye, X., Li, Y., Li, P., Yang, S., Ashraf, G., Wei, D., Chen, H., Shen, H., Kong, J., & Fang, X. (2024). An Alternating Current Electroosmotic Flow‐Based Ultrasensitive Electrochemiluminescence Microfluidic System for Ultrafast Monitoring, Detection of Proteins/miRNAs in Unprocessed Samples. Advanced Science. https://doi.org/10.1002/advs.202307840
Vancouver
Xiong H, Zhu C, Dai C, Ye X, Li Y, Li P, et al. An Alternating Current Electroosmotic Flow‐Based Ultrasensitive Electrochemiluminescence Microfluidic System for Ultrafast Monitoring, Detection of Proteins/miRNAs in Unprocessed Samples. Advanced Science. 2024. doi:10.1002/advs.202307840
BibTeX
@article{Xiong2024,
author = {Xiong, Huiwen and Zhu, Chenxin and Dai, Changhao and Ye, Xin and Li, Yuanyuan and Li, Pintao and Yang, Shuang and Ashraf, Ghazala and Wei, Dacheng and Chen, Hui and Shen, Huali and Kong, Jilie and Fang, Xueen},
title = {An Alternating Current Electroosmotic Flow‐Based Ultrasensitive Electrochemiluminescence Microfluidic System for Ultrafast Monitoring, Detection of Proteins/miRNAs in Unprocessed Samples},
journal = {Advanced Science},
year = {2024},
doi = {10.1002/advs.202307840}
}
EUVIMED