Interactive Multi‐Stage Robotic Positioner for Intra‐Operative MRI‐Guided Stereotactic Neurosurgery
Advanced Science · 2024-02 · 11 (7)
DOI: 10.1002/advs.202305495 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 10.12.2023. Verfasst von Zhuoliang He und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, 999077, China. Hauptthemen laut MEDLINE: Robotics, Neurosurgery. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Grants Council of Hong Kong, Multi-Scale Medical Robotics Center Ltd., Innovation and Technology Commission - Hong Kong.
Abstract (Originalsprache)
Magnetic resonance imaging (MRI) demonstrates clear advantages over other imaging modalities in neurosurgery with its ability to delineate critical neurovascular structures and cancerous tissue in high‐resolution 3D anatomical roadmaps. However, its application has been limited to interventions performed based on static pre/post‐operative imaging, where errors accrue from stereotactic frame setup, image registration, and brain shift. To leverage the powerful intra‐operative functions of MRI, e.g., instrument tracking, monitoring of physiological changes and tissue temperature in MRI‐guided bilateral stereotactic neurosurgery, a multi‐stage robotic positioner is proposed. The system positions cannula/needle instruments using a lightweight (203 g) and compact (Ø97 × 81 mm) skull‐mounted structure that fits within most standard imaging head coils. With optimized design in soft robotics, the system operates in two stages: i) manual coarse adjustment performed interactively by the surgeon (workspace of ±30°), ii) automatic fine adjustment with precise (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, 999077, China.
- Multi-Scale Medical Robotics Center, Hong Kong, 999077, China.
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Hong Kong, 999077, China.
- Department of Medical Physics and Biomedical Engineering, University College London, London, WC1E 6BT, UK.
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, WC1E 6BT, UK.
- Department of Mechanical Engineering and Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218, USA.
ORCID-Profile: Zhuoliang He, Ka-Wai Kwok
Förderung
- Research Grants Council of Hong Kong
- Multi-Scale Medical Robotics Center Ltd.
- Innovation and Technology Commission - Hong Kong
Zitieren
APA
He, Z., Dai, J., Ho, J. D., Tong, H. S., Wang, X., Fang, G., Liang, L., Cheung, C. L., Guo, Z., Chang, H. C., Iordachita, I., Taylor, R. H., Poon, W. S., Chan, D. T., & Kwok, K. W. (2024). Interactive Multi‐Stage Robotic Positioner for Intra‐Operative MRI‐Guided Stereotactic Neurosurgery. Advanced Science, 11(7). https://doi.org/10.1002/advs.202305495
Vancouver
He Z, Dai J, Ho JD, Tong HS, Wang X, Fang G, et al. Interactive Multi‐Stage Robotic Positioner for Intra‐Operative MRI‐Guided Stereotactic Neurosurgery. Advanced Science. 2024;11(7). doi:10.1002/advs.202305495
BibTeX
@article{He2024,
author = {He, Zhuoliang and Dai, Jing and Ho, Justin Di-Lang and Tong, Hon-Sing and Wang, Xiaomei and Fang, Ge and Liang, Liyuan and Cheung, Chim-Lee and Guo, Ziyan and Chang, Hing-Chiu and Iordachita, Iulian and Taylor, Russell H and Poon, Wai-Sang and Chan, Danny Tat-Ming and Kwok, Ka-Wai},
title = {Interactive Multi‐Stage Robotic Positioner for Intra‐Operative MRI‐Guided Stereotactic Neurosurgery},
journal = {Advanced Science},
year = {2024},
volume = {11},
number = {7},
doi = {10.1002/advs.202305495}
}
EUVIMED