Electroceuticals for Regeneration of Long Nerve Gap Using Biodegradable Conductive Conduits and Implantable Wireless Stimulator
Advanced Science · 2023-08 · 10 (24)
DOI: 10.1002/advs.202302632 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Science, online erschienen am 20.06.2023. Verfasst von Jio Kim und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, Seoul National University, Seoul, 08826, Republic of Korea. Hauptthemen laut MEDLINE: Axons, Nerve Regeneration. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation (NRF), Republic of Korea.
Abstract (Originalsprache)
Regeneration of over 10 mm long peripheral nerve defects remains a challenge due to the failure of regeneration by prolonged axotomy and denervation occurring in long‐term recovery. Recent studies reveal that conductive conduits and electrical stimulation accelerate the regeneration of long nerve defects. In this study, an electroceutical platform combining a fully biodegradable conductive nerve conduit and a wireless electrical stimulator is proposed to maximize the therapeutic effect on nerve regeneration. Fully biodegradable nerve conduit fabricated using molybdenum (Mo) microparticles and polycaprolactone (PCL) can eliminate the unwanted effects of non‐degradable implants, which occupy nerve paths and need to be removed through surgery increasing the risk of complications. The electrical and mechanical properties of Mo/PCL conduits are optimized by controlling the amounts of Mo and tetraglycol lubricant. The dissolution behavior and electrical conductivity of biodegradable nerve conduits in the biomimetic solutions are also evaluated. In in vivo experiments, the integrated strategy of a conductive Mo/PCL conduit with controlled therapeutic electrical stimulation shows accelerated axon regeneration for long sciatic nerve defects in rats compared to the use of the Mo/PCL conduit without stimulation and has a significant therapeutic effect based on the results obtained from the functional recovery test.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Materials Science and Engineering, Seoul National University, Seoul, 08826, Republic of Korea.
- Department of Nanobiomedical Science and BK21 NBM Global Research Center for Regenerative Medicine, Dankook University, Cheonan, 31116, Republic of Korea.
- Department of Rehabilitation Medicine, College of Medicine, Dankook University, Cheonan, 31116, Republic of Korea.
- Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan, 31116, Republic of Korea.
- Research Institute of Advanced Materials (RIAM), Seoul National University, Seoul, 08826, Republic of Korea.
- Nano Systems Institute SOFT Foundry, Seoul National University, Seoul, 08826, Republic of korea.
ORCID-Profile: Seung-Kyun Kang
Förderung
- National Research Foundation (NRF), Republic of Korea
Zitieren
APA
Kim, J., Jeon, J., Lee, J. Y., Khoroldulam, B., Choi, S. G., Bae, J. Y., Hyun, J. K., & Kang, S. K. (2023). Electroceuticals for Regeneration of Long Nerve Gap Using Biodegradable Conductive Conduits and Implantable Wireless Stimulator. Advanced Science, 10(24). https://doi.org/10.1002/advs.202302632
Vancouver
Kim J, Jeon J, Lee JY, Khoroldulam B, Choi SG, Bae JY, et al. Electroceuticals for Regeneration of Long Nerve Gap Using Biodegradable Conductive Conduits and Implantable Wireless Stimulator. Advanced Science. 2023;10(24). doi:10.1002/advs.202302632
BibTeX
@article{Kim2023,
author = {Kim, Jio and Jeon, Jooik and Lee, Ju-Yong and Khoroldulam, Badamgarav and Choi, Sung-Geun and Bae, Jae-Young and Hyun, Jung Keun and Kang, Seung-Kyun},
title = {Electroceuticals for Regeneration of Long Nerve Gap Using Biodegradable Conductive Conduits and Implantable Wireless Stimulator},
journal = {Advanced Science},
year = {2023},
volume = {10},
number = {24},
doi = {10.1002/advs.202302632}
}
EUVIMED