Electroosmotically Driven Casson Blood Flow in Stenosed Arteries Using the Levenberg–Marquardt Algorithm
Advanced Theory and Simulations · 2026-07 · 9 (7)
DOI: 10.1002/adts.70455 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Theory and Simulations, online erschienen am 30.06.2026. Verfasst von Sidra Batool und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
To develop a novel mathematical model of Casson blood flow through a stenosed artery under electroosmotic and thermal transport effects, this study explores a CFD‐based artificial intelligence (AI) solver that employs the Levenberg–Marquardt algorithm within a backpropagated neural network (LMA‐BPNN). This investigation examines the influence of Casson rheology, electroosmosis, and stenosis severity on blood flow through a constricted artery. A mild‐stenosis assumption is used to simplify the governing equations, and the system is solved analytically using the DSolve command in Mathematica. For the proposed LMA‐BPNN model, the dataset is generated using analytical solutions and comprises nine scenarios with various flow properties, including electric field, axial velocity, and heat transfer. of data is utilized for training, for validation, and for testing. Error histograms, performance evaluation, correlation indices, and regression analysis are used to assess the precision and effectiveness of LMA‐BPNN, with MSE ranging from to . ANN‐predicted findings are further presented using graphs and tables for axial velocity and heat transfer. With applications in microfluidics, drug delivery, and biomedical device optimization, results demonstrate the potential of CFD‐AI‐driven solvers as a fast, reliable, and accurate tool for modeling complicated biofluidic systems.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Batool, S., Bo, D., & Noreen, S. (2026). Electroosmotically Driven Casson Blood Flow in Stenosed Arteries Using the Levenberg–Marquardt Algorithm. Advanced Theory and Simulations, 9(7). https://doi.org/10.1002/adts.70455
Vancouver
Batool S, Bo D, Noreen S. Electroosmotically Driven Casson Blood Flow in Stenosed Arteries Using the Levenberg–Marquardt Algorithm. Advanced Theory and Simulations. 2026;9(7). doi:10.1002/adts.70455
BibTeX
@article{Batool2026,
author = {Batool, Sidra and Bo, Dong and Noreen, Saima},
title = {Electroosmotically Driven Casson Blood Flow in Stenosed Arteries Using the Levenberg–Marquardt Algorithm},
journal = {Advanced Theory and Simulations},
year = {2026},
volume = {9},
number = {7},
doi = {10.1002/adts.70455}
}
EUVIMED