EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ruthenium(II) and Osmium(II) Probes Based on the BODIPY Fluorophore for the Detection of Carbon Monoxide and Viscosity in Biological Environments

Jonathan A. Robson, Rian A. Hendley, Markéta Kubánková, Steffan D. James, Victoria García‐Giner, Marina K. Kuimova, James D. E. T. Wilton‐Ely

Advanced Sensor Research · 2026-07 · 5 (7)

DOI: 10.1002/adsr.70177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Sensor Research, online erschienen am 19.07.2026. Verfasst von Jonathan A. Robson und 6 weiteren Autor:innen. Die Arbeit nennt 89 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Carbon monoxide (CO) detection in biological environments requires robust, well‐defined probes that react rapidly and selectively with CO to deliver a fluorescence response. A pyridyl‐BODIPY fluorophore was used to prepare a family of ruthenium and osmium vinyl complexes. Modification with water‐solubilising units resulted in improved compatibility with aqueous media. When the BODIPY fluorophore was attached to the metal centre through the vinyl ligand, its emission was initially quenched. Reaction with CO caused a revival in the emission, providing a highly sensitive mechanism for detection of this analyte. The probes showed excellent stability and selectivity for CO over other species present in the cellular matrix and showed no toxicity at the concentrations used for sensing. The most effective CO probe displayed a 24‐fold increase in fluorescence when treated with CO. This led to experiments in cellulo which revealed that the CO produced by an increase in HO‐1 activity under hypoxic conditions could be detected. One of the complex designs was used as a viscosity‐sensitive molecular rotor, providing localized viscosity information. This led to the first demonstration of simultaneous CO and viscosity measurement, which revealed that an increase in heme oxygenase 1 (HO‐1) expression caused a decrease in cellular viscosity.

Förderung

  • Engineering and Physical Sciences Research Council

Zitieren

APA

Robson, J. A., Hendley, R. A., Kubánková, M., James, S. D., García‐Giner, V., Kuimova, M. K., & Wilton‐Ely, J. D. E. T. (2026). Ruthenium(II) and Osmium(II) Probes Based on the BODIPY Fluorophore for the Detection of Carbon Monoxide and Viscosity in Biological Environments. Advanced Sensor Research, 5(7). https://doi.org/10.1002/adsr.70177

Vancouver

Robson JA, Hendley RA, Kubánková M, James SD, García‐Giner V, Kuimova MK, et al. Ruthenium(II) and Osmium(II) Probes Based on the BODIPY Fluorophore for the Detection of Carbon Monoxide and Viscosity in Biological Environments. Advanced Sensor Research. 2026;5(7). doi:10.1002/adsr.70177

BibTeX
@article{Robson2026,
  author = {Robson, Jonathan A. and Hendley, Rian A. and Kubánková, Markéta and James, Steffan D. and García‐Giner, Victoria and Kuimova, Marina K. and Wilton‐Ely, James D. E. T.},
  title = {Ruthenium(II) and Osmium(II) Probes Based on the BODIPY Fluorophore for the Detection of Carbon Monoxide and Viscosity in Biological Environments},
  journal = {Advanced Sensor Research},
  year = {2026},
  volume = {5},
  number = {7},
  doi = {10.1002/adsr.70177}
}
Kostenlos starten →