Breathing‐Induced Airflow Measurements at Multiple Positions in a 3D‐Printed Nasal Cavity
Advanced Sensor Research · 2026-06 · 5 (6)
DOI: 10.1002/adsr.70162 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Sensor Research, online erschienen am 01.06.2026. Verfasst von Kota Shiba und 11 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Evaluating nasal cavity airflow is crucial in both fundamental science and clinical settings. While rhinomanometry (RM) effectively assesses global nasal resistance, developing alternative methods for detailed local structural evaluation remains challenging. Here, we report an approach to measure local pressure at multiple positions in the nasal cavity using 3D‐printed models created based on computed tomography data of five healthy individuals. This approach records multiple pressure differential values at arbitrary positions in the nasal cavity during a breathing‐like inhalation/exhalation cycle. The measured data are unique to the corresponding individuals and correlate well with the RM results from human‐assisted breathing using the 3D‐printed models. Our experimental approach will open up possibilities for a deeper understanding of the relationship between fluid dynamics in the nasal cavity and practical air flow in the nasal cavity.
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Shiba, K., Saito, K., Tei, M., Yonezawa, N., Sekine, R., Nagai, M., Tanaka, H., Kishimoto, Y., Tamura, R., Yoshikawa, G., Otori, N., & Mori, E. (2026). Breathing‐Induced Airflow Measurements at Multiple Positions in a 3D‐Printed Nasal Cavity. Advanced Sensor Research, 5(6). https://doi.org/10.1002/adsr.70162
Vancouver
Shiba K, Saito K, Tei M, Yonezawa N, Sekine R, Nagai M, et al. Breathing‐Induced Airflow Measurements at Multiple Positions in a 3D‐Printed Nasal Cavity. Advanced Sensor Research. 2026;5(6). doi:10.1002/adsr.70162
BibTeX
@article{Shiba2026,
author = {Shiba, Kota and Saito, Kayoko and Tei, Masayoshi and Yonezawa, Nagomi and Sekine, Rumi and Nagai, Monami and Tanaka, Hirotaka and Kishimoto, Yuji and Tamura, Ryo and Yoshikawa, Genki and Otori, Nobuyoshi and Mori, Eri},
title = {Breathing‐Induced Airflow Measurements at Multiple Positions in a 3D‐Printed Nasal Cavity},
journal = {Advanced Sensor Research},
year = {2026},
volume = {5},
number = {6},
doi = {10.1002/adsr.70162}
}
EUVIMED