EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Seamlessly Machine‐Knitted Multi‐Sensor Garment to Monitor and Quantify Dynamic Upper Body Movement

Ying Yi Tan, Ujjaval Gupta, Pei Zhi Chia, Christyasto Priyonggo Pambudi, Benjamin En How Lim, Gim Song Soh, Hong Yee Low

Advanced Sensor Research · 2025-12 · 4 (12)

DOI: 10.1002/adsr.202500067 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Sensor Research, online erschienen am 30.09.2025. Verfasst von Ying Yi Tan und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hyundai Motor Group.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Smart garments offer good potential to monitor and assess dynamic upper body movements, particularly from the shoulder joint with its 3 Degrees of Freedom (DOF). In this paper, a customizable lightweight smart shirt is proposed, which is designed and manufactured using Computer Numerical Control (CNC) knitting technology. This automated textile manufacturing method enables the seamless fabrication of multiple piezoresistive sensors at designated positions and at a high resolution within the garment. The paper presents a proof‐of‐concept system that can record both shoulder and elbow joint motions in a non‐obtrusive and non‐invasive manner. This system consists of: i) a fully CNC knitted smart crop top with multi‐material stretchable strain sensors and interconnects; ii) a regression model, trained on several full Range of Motion (ROM) upper body actions, to convert these sensor signals into shoulder and elbow joint angles; iii) an assessment using an ergonomics software to translate these converted joint angles into muscle fatigue markers. To validate the workflow, the subject performed a pick‐and‐hold activity outside of the regression model's training dataset. Subsequently, the joint angles of the subject performing this pick‐and‐hold activity, converted from the smart garment, are compared with joint angle data from the Vicon motion capture system. Comparing the ergonomics software outputs from both datasets shows good agreement with overall low root mean square errors, the highest being 0.787% for maximum voluntary contraction (%MVC) and 1.896% for duty cycle limit (%DC).

Förderung

  • Hyundai Motor Group

Zitieren

APA

Tan, Y. Y., Gupta, U., Chia, P. Z., Pambudi, C. P., Lim, B. E. H., Soh, G. S., & Low, H. Y. (2025). Seamlessly Machine‐Knitted Multi‐Sensor Garment to Monitor and Quantify Dynamic Upper Body Movement. Advanced Sensor Research, 4(12). https://doi.org/10.1002/adsr.202500067

Vancouver

Tan YY, Gupta U, Chia PZ, Pambudi CP, Lim BEH, Soh GS, et al. Seamlessly Machine‐Knitted Multi‐Sensor Garment to Monitor and Quantify Dynamic Upper Body Movement. Advanced Sensor Research. 2025;4(12). doi:10.1002/adsr.202500067

BibTeX
@article{Tan2025,
  author = {Tan, Ying Yi and Gupta, Ujjaval and Chia, Pei Zhi and Pambudi, Christyasto Priyonggo and Lim, Benjamin En How and Soh, Gim Song and Low, Hong Yee},
  title = {Seamlessly Machine‐Knitted Multi‐Sensor Garment to Monitor and Quantify Dynamic Upper Body Movement},
  journal = {Advanced Sensor Research},
  year = {2025},
  volume = {4},
  number = {12},
  doi = {10.1002/adsr.202500067}
}
Kostenlos starten →