A Performance Comparison Between Organic Electrochemical Transistor and Electrode Configurations for Enzymatic Sensing
Advanced Sensor Research · 2024-06 · 3 (6)
DOI: 10.1002/adsr.202300188 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Sensor Research, online erschienen am 03.03.2024. Verfasst von Abdulelah Saleh und 7 weiteren Autor:innen. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Abdullah University of Science and Technology.
Abstract (Originalsprache)
Organic electrochemical transistors (OECTs) excel at biosensing due to their high amplification factor, which allows for detecting low analyte concentrations and picking up weak physiological signals. One prominent use of OECT is in enzymatic metabolite sensing, with the OECT claimed to have a superior low limit of detection and enhanced sensitivity compared to conventional two or three electrode‐based setups. However, there has yet to be a direct comparative study on the performance metrics of these sensor configurations under unified conditions. Here, the glucose sensing performance of an enzyme‐immobilized electrode is systematically examined in two types of devices that have the same geometrical relations: the first one is a traditional 2‐ or 3‐electrode configuration where the sensing electrode is the working electrode, and in the second one, the enzymatic electrode serves as the gate electrode of an OECT. While benchmarking the performance of OECT technology for enzyme‐based metabolite sensing, this study provides insights into the operation mechanism of OECT‐based enzymatic sensors. These results can help to design more efficient OECT‐based circuits to transduce biological events that involve redox reactions.
Förderung
- King Abdullah University of Science and Technology
Zitieren
APA
Saleh, A., Wustoni, S., Salvigni, L., Koklu, A., Druet, V., Surgailis, J., Nayak, P. D., & Inal, S. (2024). A Performance Comparison Between Organic Electrochemical Transistor and Electrode Configurations for Enzymatic Sensing. Advanced Sensor Research, 3(6). https://doi.org/10.1002/adsr.202300188
Vancouver
Saleh A, Wustoni S, Salvigni L, Koklu A, Druet V, Surgailis J, et al. A Performance Comparison Between Organic Electrochemical Transistor and Electrode Configurations for Enzymatic Sensing. Advanced Sensor Research. 2024;3(6). doi:10.1002/adsr.202300188
BibTeX
@article{Saleh2024,
author = {Saleh, Abdulelah and Wustoni, Shofarul and Salvigni, Luca and Koklu, Anil and Druet, Victor and Surgailis, Jokubas and Nayak, Prem D. and Inal, Sahika},
title = {A Performance Comparison Between Organic Electrochemical Transistor and Electrode Configurations for Enzymatic Sensing},
journal = {Advanced Sensor Research},
year = {2024},
volume = {3},
number = {6},
doi = {10.1002/adsr.202300188}
}
EUVIMED