Water‐Based Conductive Ink Formulations for Enzyme‐Based Wearable Biosensors
Advanced Sensor Research · 2024-03 · 3 (3)
DOI: 10.1002/adsr.202300036 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Sensor Research, online erschienen am 25.04.2023. Verfasst von Angelo Tricase und 12 weiteren Autor:innen. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Academy of Finland, H2020 European Research Council.
Abstract (Originalsprache)
Herein, this work reports the first example of second‐generation wearable biosensor arrays based on a printed electrode technology involving a water‐based graphite ink, for the simultaneous detection of l ‐lactate and d ‐glucose. The water‐based graphite ink is deposited onto a flexible polyethylene terephthalate sheet, namely stencil‐printed graphite (SPG) electrodes, and further modified with [Os(bpy) 2 (Cl)(PVI) 10 ] as an osmium redox polymer to shuttle the electrons from the redox center of lactate oxidase from Aerococcus viridans (LOx) and gluocose oxidase from Aspergillus niger (GOx). The proposed biosensor array exhibits a limit of detection as low as (9.0 ± 1.0) × 10 −6 m for LOx/SPG‐[Os(bpy) 2 (Cl)(PVI) 10 ] and (3.0 ± 0.5) × 10 −6 m for GOx/SPG‐[Os(bpy) 2 (Cl)(PVI) 10 ], a sensitivity as high as 1.32 μA m m −1 for LOx/SPG‐[Os(bpy) 2 (Cl)(PVI) 10 ] and 28.4 μA m m −1 for GOx/SPG‐[Os(bpy) 2 (Cl)(PVI) 10 ]. The technology is also selective when tested in buffer and artificial sweat and is endowed with an operational/storage stability of ≈80% of the initial signal retained after 20 days. Finally, the proposed array is integrated in a wristband and successfully tested for the continuous monitoring of l ‐lactate and d ‐glucose in a healthy volunteer during daily activity. This is foreseen as a real‐time wearable device for sport‐medicine and healthcare applications.
Förderung
- Academy of Finland
- H2020 European Research Council
Zitieren
APA
Tricase, A., Imbriano, A., Valentino, M., Ditaranto, N., Macchia, E., Franco, C. D., Kidayaveettil, R., Leech, D., Piscitelli, M., Scamarcio, G., Perchiazzi, G., Torsi, L., & Bollella, P. (2024). Water‐Based Conductive Ink Formulations for Enzyme‐Based Wearable Biosensors. Advanced Sensor Research, 3(3). https://doi.org/10.1002/adsr.202300036
Vancouver
Tricase A, Imbriano A, Valentino M, Ditaranto N, Macchia E, Franco CD, et al. Water‐Based Conductive Ink Formulations for Enzyme‐Based Wearable Biosensors. Advanced Sensor Research. 2024;3(3). doi:10.1002/adsr.202300036
BibTeX
@article{Tricase2024,
author = {Tricase, Angelo and Imbriano, Anna and Valentino, Marlene and Ditaranto, Nicoletta and Macchia, Eleonora and Franco, Cinzia Di and Kidayaveettil, Reshma and Leech, Dónal and Piscitelli, Matteo and Scamarcio, Gaetano and Perchiazzi, Gaetano and Torsi, Luisa and Bollella, Paolo},
title = {Water‐Based Conductive Ink Formulations for Enzyme‐Based Wearable Biosensors},
journal = {Advanced Sensor Research},
year = {2024},
volume = {3},
number = {3},
doi = {10.1002/adsr.202300036}
}
EUVIMED