EUVIMEDEUVIMED entdecken
Crossref

Unobtrusive Swallow Monitoring Enabled by Conformal IONOGEL Biopotential Electrodes and Machine Learning

Penghao Dong, Jasmine Ives, Ethan Garcia, Christopher Caporusso, Polina Bragina, Cassandra Laguatan, Shanshan Yao

Advanced Materials Technologies · 2025-08 · 10 (16)

DOI: 10.1002/admt.202500229 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials Technologies, online erschienen am 19.05.2025. Verfasst von Penghao Dong und 6 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: National Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dysphagia or difficulty swallowing is caused by the failure of neurological pathways to properly activate swallowing muscles. Current electromyography (EMG) systems for dysphagia monitoring are bulky and rigid, limiting their potential for long‐term and unobtrusive use. To address this, a machine learning‐assisted wearable EMG system is presented, utilizing self‐adhesive, skin‐conformal, semi‐transparent, and robust ionic gel electrodes. The presented electrodes possess good conductivity, superior skin contact, and good transmittance, ensuring high‐fidelity EMG sensing without impeding daily activities. Moreover, the optimized material and structural designs ensure wearing comfort and conformable skin‐electrode contact, allowing for long‐term monitoring with high accuracy. Machine learning and mel‐frequency cepstral coefficient techniques are employed to classify swallowing events based on food types and volumes. Through an analysis of electrode placement on the chin and neck, the proposed system is able to effectively distinguish between different food types and water volumes using a small number of channels, making it suitable for continuous dysphagia monitoring. This work represents an advancement in machine learning assisted EMG systems for the classification and regression of swallowing events, paving the way for more efficient, unobtrusive, and long‐term dysphagia monitoring systems.

Förderung

  • National Science Foundation

Zitieren

APA

Dong, P., Ives, J., Garcia, E., Caporusso, C., Bragina, P., Laguatan, C., & Yao, S. (2025). Unobtrusive Swallow Monitoring Enabled by Conformal IONOGEL Biopotential Electrodes and Machine Learning. Advanced Materials Technologies, 10(16). https://doi.org/10.1002/admt.202500229

Vancouver

Dong P, Ives J, Garcia E, Caporusso C, Bragina P, Laguatan C, et al. Unobtrusive Swallow Monitoring Enabled by Conformal IONOGEL Biopotential Electrodes and Machine Learning. Advanced Materials Technologies. 2025;10(16). doi:10.1002/admt.202500229

BibTeX
@article{Dong2025,
  author = {Dong, Penghao and Ives, Jasmine and Garcia, Ethan and Caporusso, Christopher and Bragina, Polina and Laguatan, Cassandra and Yao, Shanshan},
  title = {Unobtrusive Swallow Monitoring Enabled by Conformal IONOGEL Biopotential Electrodes and Machine Learning},
  journal = {Advanced Materials Technologies},
  year = {2025},
  volume = {10},
  number = {16},
  doi = {10.1002/admt.202500229}
}
Kostenlos starten →