Ultrasensitive Flexible Pressure Sensors with Broad Linear Detection Range Enabled by Magnetically Induced Self‐Assembled Parallel Circuit
Advanced Materials Technologies · 2024-04 · 9 (8)
DOI: 10.1002/admt.202301646 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials Technologies, online erschienen am 16.02.2024. Verfasst von Zeying Zhang und 12 weiteren Autor:innen. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, China Postdoctoral Science Foundation.
Abstract (Originalsprache)
Flexible pressure sensors have attracted intensive interest for promising applications in healthcare monitoring and flexible electronic devices. Nonetheless, designing flexible pressure sensors to achieve both ultrahigh sensitivity (>1000 kPa −1 ) and an extensive linear range (>50 kPa) poses a significant challenge. In this study, a facile magnetic‐facilitated self‐assembly parallel circuit strategy to prepare high‐performance flexible pressure sensors in Nickel particles/polydimethylsiloxane (Ni/PDMS) matrices is proposed. The optimized magnetic‐induced Ni/PDMS piezoresistive sensor (MANPS) exhibits an ultrahigh sensitivity of 3707 kPa −1 over a wide broad linear range (0–80 kPa), and excellent durability with the capability of withstanding 2000 pressure cycles. The MANPS is able to detect a broad range of pressures from pulse to plantar pressures (≈60 kPa), demonstrating great potential for whole‐body healthcare monitoring. Additionally, the sensor is further assembled into an array configuration (2 × 5 pixels) for the assessment of plantar pressure distribution. Importantly, the sensitivity and linear range of the MANPS can be readily adjusted by modifying the mixing ratio of the curing agent, thereby significantly broadening its potential applications.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- China Postdoctoral Science Foundation
Zitieren
APA
Zhang, Z., Qiao, J., Peng, B., Dong, G., Zhang, Q., Zhan, W., Xue, L., Zhang, C., Wu, J., Peng, N., Jiang, Z., Liu, M., & Zhang, X. (2024). Ultrasensitive Flexible Pressure Sensors with Broad Linear Detection Range Enabled by Magnetically Induced Self‐Assembled Parallel Circuit. Advanced Materials Technologies, 9(8). https://doi.org/10.1002/admt.202301646
Vancouver
Zhang Z, Qiao J, Peng B, Dong G, Zhang Q, Zhan W, et al. Ultrasensitive Flexible Pressure Sensors with Broad Linear Detection Range Enabled by Magnetically Induced Self‐Assembled Parallel Circuit. Advanced Materials Technologies. 2024;9(8). doi:10.1002/admt.202301646
BibTeX
@article{Zhang2024,
author = {Zhang, Zeying and Qiao, Jiacheng and Peng, Bin and Dong, Guohua and Zhang, Qi and Zhan, Wang and Xue, Li and Zhang, Cuiling and Wu, Jingen and Peng, Niancai and Jiang, Zhuangde and Liu, Ming and Zhang, Xiaohui},
title = {Ultrasensitive Flexible Pressure Sensors with Broad Linear Detection Range Enabled by Magnetically Induced Self‐Assembled Parallel Circuit},
journal = {Advanced Materials Technologies},
year = {2024},
volume = {9},
number = {8},
doi = {10.1002/admt.202301646}
}
EUVIMED