Intervertebral Disc‐on‐a‐Chip MF : A New Model for Mouse Disc Culture via Integrating Mechanical Loading and Dynamic Media Flow
Advanced Materials Technologies · 2023-11 · 8 (21)
DOI: 10.1002/admt.202300606 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials Technologies, online erschienen am 27.08.2023. Verfasst von Wanqing Xie und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, University of Virginia, Charlottesville, VA 22908, USA. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIAMS NIH HHS, NIDDK NIH HHS, North American Spine Society.
Abstract (Originalsprache)
This study aims to develop an ex vivo organ‐on‐a‐chip model, intervertebral Disc‐on‐a‐Chip MF , to investigate integrated effects of mechanical loading and nutrition on disc health. The system consists of a detachable multilayer microfluidic chip, a Computer‐Arduino‐based control system, and a mechanical loading unit, which are optimized for accurate axial force measurement and the maintenance of a 21‐day ex vivo disc culture. To ensure accuracy of axial force, the axial mechanical loading regimen is optimized, using the Computer‐Arduino‐based system and low‐profile force sensors (LPFS) to control the mechanical loading unit, and the force distribution on the disc surface is modeled by computational simulation. A 21‐day ex vivo disc culture is demonstrated using the Disc‐on‐a‐Chip MF system, with optimized mechanical loading (0.02 MPa at 1Hz, 1.5 hr day −1 ) and flow rate (1 µL min −1 ). The structural integrity, collagen breakdown, catabolic enzyme activities, and disc cell and collagen alignment reveal that the on‐chip cultured discs exhibit a preferred disc health similar to that of native discs for up to 21 days, while discs in a static culture show degenerative changes. The mouse Disc‐on‐a‐Chip MF system mimics in vivo disc microenvironment and provides a valuable platform for studying the effects of various factors on disc health and degeneration and testing new therapies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, University of Virginia, Charlottesville, VA 22908, USA.
- Department of Surgery, University of Virginia, 345 Cripell Drive, Charlottesville, VA 22908, USA.
- Department of Mechanical and Aerospace Engineering, University of Virginia, 122 Engineer's Way, Charlottesville, VA 22904, USA.
- Current address: Department of Orthopaedic Surgery, Beijing Chaoyang Hospital, Capital Medical University, Beijing, China.
- Department of BioMolecular Science, University of Mississippi, Oxford, MS 38677, USA.
- Department of Visceral Surgery and Transplantation, University of Zurich Hospital, 8091 Zürich, Switzerland.
Förderung
- NIAMS NIH HHS
- NIDDK NIH HHS
- North American Spine Society
Zitieren
APA
Xie, W., Xing, Y., Xiao, L., Zhang, P., Oh, R., Zhang, Y., Yu, X., He, Y., Oh, E. G., Cao, R., Ramasubramanian, M. K., Wang, Y., Jin, L., Oberhozler, J., & Li, X. (2023). Intervertebral Disc‐on‐a‐Chip MF : A New Model for Mouse Disc Culture via Integrating Mechanical Loading and Dynamic Media Flow. Advanced Materials Technologies, 8(21). https://doi.org/10.1002/admt.202300606
Vancouver
Xie W, Xing Y, Xiao L, Zhang P, Oh R, Zhang Y, et al. Intervertebral Disc‐on‐a‐Chip MF : A New Model for Mouse Disc Culture via Integrating Mechanical Loading and Dynamic Media Flow. Advanced Materials Technologies. 2023;8(21). doi:10.1002/admt.202300606
BibTeX
@article{Xie2023,
author = {Xie, Wanqing and Xing, Yuan and Xiao, Li and Zhang, Pu and Oh, Richard and Zhang, Yangpu and Yu, Xiaoyu and He, Yi and Oh, Eunha G and Cao, Ruofan and Ramasubramanian, Melur K and Wang, Yong and Jin, Li and Oberhozler, Jose and Li, Xudong},
title = {Intervertebral Disc‐on‐a‐Chip MF : A New Model for Mouse Disc Culture via Integrating Mechanical Loading and Dynamic Media Flow},
journal = {Advanced Materials Technologies},
year = {2023},
volume = {8},
number = {21},
doi = {10.1002/admt.202300606}
}