Understanding Operando Water Management in Hydroxide‐Exchange‐Membrane Fuel Cells
Advanced Materials Interfaces · 26.03.2026
DOI: 10.1002/admi.202600001 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials Interfaces, online erschienen am 26.03.2026. Verfasst von Catherine M. Weiss und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hydrogen and Fuel Cell Technologies Office, Advanced Research Projects Agency.
Abstract (Originalsprache)
The water balance in hydroxide‐exchange‐membrane fuel cells (HEMFCs) is a key challenge for improved performance and durability, intimately linked with the various interfaces and coupled phenomena. For every 4 electrons produced, 4 water molecules are generated in the anode and 2 consumed in the cathode, while electroosmosis transports water across the HEM from the cathode to the anode. Consequently, a concentration gradient drives water back, from anode to cathode. Ineffective water management could lead to cathode dry‐out, limiting reaction rate and causing ionomer degradation, or to anode flooding. To address these concerns, it is critical to measure the water transport operando . Herein, a home‐built water‐flux station is used to measure total water flux during cell operation with different inlet relative humidities and back pressures. Increasing the HEM thickness fourfold decreases the water flux at high current density, and utilizing microporous layers on both the anode and cathode decreases the water flux from the anode to the cathode. However, the most significant variable in changing the water flux was found by increasing the anode back pressure. Furthermore, humidity cycling significantly changed electrochemical performance without affecting the overall water fluxes. These findings can be translated to other devices utilizing an HEM.
Förderung
- Hydrogen and Fuel Cell Technologies Office
- Advanced Research Projects Agency
Zitieren
APA
Weiss, C. M., Wang, S., Setzler, B. P., Yan, Y., & Weber, A. Z. (2026). Understanding Operando Water Management in Hydroxide‐Exchange‐Membrane Fuel Cells. Advanced Materials Interfaces. https://doi.org/10.1002/admi.202600001
Vancouver
Weiss CM, Wang S, Setzler BP, Yan Y, Weber AZ. Understanding Operando Water Management in Hydroxide‐Exchange‐Membrane Fuel Cells. Advanced Materials Interfaces. 2026. doi:10.1002/admi.202600001
BibTeX
@article{Weiss2026,
author = {Weiss, Catherine M. and Wang, Shiyi and Setzler, Brian P. and Yan, Yushan and Weber, Adam Z.},
title = {Understanding Operando Water Management in Hydroxide‐Exchange‐Membrane Fuel Cells},
journal = {Advanced Materials Interfaces},
year = {2026},
doi = {10.1002/admi.202600001}
}
EUVIMED