EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

From Water Vapor Transmission Rate (WVTR) to Intrinsic Water Vapor Permeability (WVP)

Xianke Feng iD, Winston Wang iD, Hongbian Li, K Ravi-Chandar, Benny D Freeman iD, Rui Huang iD, Nanshu Lu

Advanced Materials · 31.10.2026

DOI: 10.1002/adma.75578 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 31.10.2026. Verfasst von Xianke Feng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas, USA. Die Arbeit nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Science Foundation, NIH HHS, Army Research Office.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Water vapor transmission rate (WVTR) is widely used to assess breathability in skin‐interfaced electronics. In gravimetric wet‐cup tests, however, the measured flux depends on transport through both the membrane and the apparatus. Apparatus resistance can dominate measurements of highly permeable membranes. Evaporation, headspace transport, membrane permeation, and external vapor spreading are modeled as resistances in series under a common chemical‐potential driving force. The apparatus coefficients are calibrated using open‐cup measurements in the same setup, independently of the reference permeability. For poly(dimethylsiloxane) membranes, where membrane resistance dominates, both a literature air‐gap correction and the calibrated model reduce deviations from the reference. For a highly permeable anion‐exchange membrane (AEM), the air‐gap correction becomes unstable. Relative to a dynamic sweep‐cell reference, the calibrated model reduces mean absolute relative deviation from 49.8% for classical conversion to 6.2%. It also provides model‐based criteria for geometry selection and measurement duration, together with a procedure for converting WVTR to water vapor permeability (WVP).

Schlagwörter

Stichwörter der Autor:innen

gravimetric cup methodthermodynamic modelingwater vapor permeabilitywater vapor transmission ratewet‐cup calibration

Autor:innen und Institutionen

  • Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas, USA.
  • McKetta Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas, USA.
  • Department of Biomedical Engineering, Chandra Family Department of Electrical and Computer Engineering, Walker Department of Mechanical Engineering, Texas Materials Institute, The University of Texas at Austin, Austin,…

ORCID-Profile: Xianke Feng, Winston Wang, Benny D Freeman, Rui Huang

Förderung

  • National Science Foundation
  • NIH HHS
  • Army Research Office
  • U.S. Department of Energy, Office of Science, Basic Energy Sciences
  • National Institutes of Health

Zitieren

APA

Feng, X., Wang, W., Li, H., Ravi-Chandar, K., Freeman, B. D., Huang, R., & Lu, N. (2026). From Water Vapor Transmission Rate (WVTR) to Intrinsic Water Vapor Permeability (WVP). Advanced Materials. https://doi.org/10.1002/adma.75578

Vancouver

Feng X, Wang W, Li H, Ravi-Chandar K, Freeman BD, Huang R, et al. From Water Vapor Transmission Rate (WVTR) to Intrinsic Water Vapor Permeability (WVP). Advanced Materials. 2026. doi:10.1002/adma.75578

BibTeX
@article{Feng2026,
  author = {Feng, Xianke and Wang, Winston and Li, Hongbian and Ravi-Chandar, K and Freeman, Benny D and Huang, Rui and Lu, Nanshu},
  title = {From Water Vapor Transmission Rate (WVTR) to Intrinsic Water Vapor Permeability (WVP)},
  journal = {Advanced Materials},
  year = {2026},
  doi = {10.1002/adma.75578}
}
Kostenlos starten →