EUVIMEDEUVIMED entdecken
Crossref

Ultrasound‐Triggered Tendon–Bone Comb With Axially Graded Electrical Gradients for Tendon–Bone Interface Integration

Xu He, Fan Wang iD, Si Tian, Peng Zou, Wang Han, Xinhe Li, Zijie Wang, Jindong Tan, Juan Wang, Dingqun Bai iD, Xiaoyu Han

Advanced Materials · 2026-11 · 38 (62)

DOI: 10.1002/adma.75049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 18.09.2026. Verfasst von Xu He und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Medicine, Key Laboratory of Physical Medicine and Precision Rehabilitation of Chongqing Municipal Health Commission, The…. Hauptthemen laut MEDLINE: Bone and Bones, Tendons, Ultrasonic Waves. Die Arbeit nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Postdoctoral Fellowship Program and China Postdoctoral Science Foundation, Key Laboratory of Physical Medicine and Precision Rehabilitation of Chongqing Municipal Health Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Loss of electrophysiological guidance from endogenous fibrous‐channeled electrical conduction critically impairs repair of the injured tendon–bone interface (TBI). Clinical analysis indicates that the inconsistent efficacy of conventional electrostimulation (ES) therapy arises from the limited penetration depth and insufficient focusing capacity of electrical currents in biological tissues. In this study, we developed a tendon–bone comb, termed the gradient microneedle (GMN), to improve spatial precision of electrical‐signal delivery through multiple independent channel units and thereby promote targeted TBI regeneration. Ultrasonic acoustic radiation force was used to guide the graded distribution of piezoelectric nanoparticles within the GMN. In vitro, under ultrasonic stimulation (1 W), the GMN generated a gradient electric field that closely matched the optimal intensity required to direct the biphasic differentiation of bone marrow mesenchymal stem cells (BMSCs). In vivo studies demonstrated that the GMN increased host bone integration by 101% compared with control systems and promoted functional recovery in rat and porcine TBI injury models. Additionally, GMN‐mediated acoustic‐electrical stimulation promoted graded regeneration of the complex by triggering Ca 2 + influx and subsequently regulating the FoxO and JAK1‐STAT3 signaling pathways. Overall, this study presents a GMN that reconstructs physiological bioelectrical gradients and enhances osteointegration, offering a novel gradient ES strategy for regenerating interfacial tissues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone and BonesTendonsUltrasonic WavesAnimalsRatsMesenchymal Stem CellsSwineRats, Sprague-DawleyCell Differentiation

Stichwörter der Autor:innen

electrical channelgradient electric fieldlow‐intensity focused ultrasoundmicroneedlestendon–bone interface injury

Autor:innen und Institutionen

  • Department of Rehabilitation Medicine, Key Laboratory of Physical Medicine and Precision Rehabilitation of Chongqing Municipal Health Commission, The First Affiliated Hospital of Chongqing Medical University, Chongqing,…
  • State Key Laboratory of Ultrasound in Medicine and Engineering, Chongqing Medical University, Chongqing, P. R. China.
  • Department of Orthopaedics, Shanghai Key Laboratory For Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of…

ORCID-Profile: Fan Wang, Dingqun Bai

Förderung

  • National Natural Science Foundation of China
  • Postdoctoral Fellowship Program and China Postdoctoral Science Foundation
  • Key Laboratory of Physical Medicine and Precision Rehabilitation of Chongqing Municipal Health Commission
  • Chongqing Science and Health Joint Medical Research Key Project
  • Chongqing Municipal Science and Health Joint Youth (Physician) Scientist Program
  • the Natural Science Foundation of Chongqing Science and Technology Commission
  • Shanghai Science and Technology Program
  • "Two Hundred Talent" Program supported by Shanghai Jiao Tong University School of Medicine

Zitieren

APA

He, X., Wang, F., Tian, S., Zou, P., Han, W., Li, X., Wang, Z., Tan, J., Wang, J., Bai, D., & Han, X. (2026). Ultrasound‐Triggered Tendon–Bone Comb With Axially Graded Electrical Gradients for Tendon–Bone Interface Integration. Advanced Materials, 38(62). https://doi.org/10.1002/adma.75049

Vancouver

He X, Wang F, Tian S, Zou P, Han W, Li X, et al. Ultrasound‐Triggered Tendon–Bone Comb With Axially Graded Electrical Gradients for Tendon–Bone Interface Integration. Advanced Materials. 2026;38(62). doi:10.1002/adma.75049

BibTeX
@article{He2026,
  author = {He, Xu and Wang, Fan and Tian, Si and Zou, Peng and Han, Wang and Li, Xinhe and Wang, Zijie and Tan, Jindong and Wang, Juan and Bai, Dingqun and Han, Xiaoyu},
  title = {Ultrasound‐Triggered Tendon–Bone Comb With Axially Graded Electrical Gradients for Tendon–Bone Interface Integration},
  journal = {Advanced Materials},
  year = {2026},
  volume = {38},
  number = {62},
  doi = {10.1002/adma.75049}
}
Kostenlos starten →