Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 30.06.2026. Verfasst von Kangzhe Liu und 18 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Polymer Optoelectronic Materials and Devices, Guangdong Basic Research Center of Excellence for Energy & Information Polymer Materials, …. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Guangdong Provincial Science and Technology Plan Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Commercial photodetectors integrated on readout circuits typically operate under bias voltage, necessitating low dark current density ( J d ) to achieve high detectivity. However, suppressing J d remains a critical challenge for organic photodetectors (OPDs), particularly those operating in the short‐wave infrared (SWIR) region. Herein, we report SWIR‐OPDs that achieve ultralow J d under high bias voltage by developing a narrow bandgap p‐type polymer as the SWIR absorber, thereby establishing an alternative material platform for high‐performance SWIR‐OPDs. The new polymer PDCBT‐DTO2F adopts a push‐pull architecture comprising quaterthiophene donor units and 5,6‐dicyano‐2,1,3‐benzothiadiazole acceptor moieties. Substituting the alkyl chains on quaterthiophene units with alkoxy chains significantly enhanced the intramolecular charge transfer effect and backbone coplanarity. This modification simultaneously yielded intense SWIR absorption, high crystallinity, reduced trap density, and low energetic disorder. Through extensive device optimization, the SWIR‐OPD based on PDCBT‐DTO2F exhibited J d as low as 15.6 nA cm – 2 under −2 V and 58.1 nA cm −2 even under −5 V. Consequently, a detectivity of 1.04 × 10 12 Jones was realized at 1100 nm under −2 V bias, ranking among the best performance for SWIR‐OPDs operating under reverse bias.

Schlagwörter

Stichwörter der Autor:innen

dark currentnarrow bandgap polymerorganic photodetectorsreverse biasshort‐wave infrared

Autor:innen und Institutionen

  • Institute of Polymer Optoelectronic Materials and Devices, Guangdong Basic Research Center of Excellence for Energy & Information Polymer Materials, National Key Laboratory of Luminescent Materials and Devices, South Ch…
  • Function Hub, Advanced Materials Thrust, The Hong Kong University of Science and Technology (Guangzhou), Guangzhou, P. R. China.
  • Dongguan Key Laboratory of Interdisciplinary Science for Advanced Materials and Large-Scale Scientific Facilities, School of Physical Sciences, Great Bay University, Dongguan, P. R. China.
  • State Key Laboratory of Silicon and Advanced Semiconductor Materials, School of Materials Science and Engineering, Zhejiang University, Hangzhou, P. R. China.
  • School of Energy and Chemical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea.

ORCID-Profile: Yao Li, Jiaying Wu, Sha Liu, Yanjun Fang, Changduk Yang, Fei Huang, Chunhui Duan

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Guangdong Provincial Science and Technology Plan Project
  • Guangdong Basic and Applied Basic Research Foundation
  • Postdoctoral Fellowship Program of China Postdoctoral Science Foundation
  • China Postdoctoral Science Foundation
  • Guangzhou Municipal Science and Technology Bureau
  • National Research Foundation of Korea

Zitieren

APA

Liu, K., Luo, X., Yin, B., Yang, M., Wu, B., Li, Y., Lv, Z., Cao, Y., Wang, J., Lee, S., Chen, Y., Wu, J., Liu, S., Fang, Y., Yang, C., Wu, H., Huang, F., Cao, Y., & Duan, C. (2026). Short‐Wave Infrared Organic Photodetectors With Ultralow Dark Current Density Under Biased Operating Conditions. Advanced Materials, 38(43). https://doi.org/10.1002/adma.73895

Vancouver

Liu K, Luo X, Yin B, Yang M, Wu B, Li Y, et al. Short‐Wave Infrared Organic Photodetectors With Ultralow Dark Current Density Under Biased Operating Conditions. Advanced Materials. 2026;38(43). doi:10.1002/adma.73895

BibTeX
@article{Liu2026,
  author = {Liu, Kangzhe and Luo, Xiang and Yin, Bingyan and Yang, Mingqun and Wu, Baoqi and Li, Yao and Lv, Zhaochen and Cao, Yunhao and Wang, Jing and Lee, Seunglok and Chen, Yihui and Wu, Jiaying and Liu, Sha and Fang, Yanjun and Yang, Changduk and Wu, Hongbin and Huang, Fei and Cao, Yong and Duan, Chunhui},
  title = {Short‐Wave Infrared Organic Photodetectors With Ultralow Dark Current Density Under Biased Operating Conditions},
  journal = {Advanced Materials},
  year = {2026},
  volume = {38},
  number = {43},
  doi = {10.1002/adma.73895}
}
Kostenlos starten →