An Immunocompatible Conductive Hydrogel Via Anion‐π Interlocking as an Injectable Bridge for Sustained Bioelectronic Interfacing
Advanced Materials · 2026-04 · 38 (21)
DOI: 10.1002/adma.72820 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 18.03.2026. Verfasst von Zihao Zhu und 9 weiteren Autor:innen. Beteiligte Einrichtung: MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, Z…. Hauptthemen laut MEDLINE: Hydrogels, Biocompatible Materials, Electric Conductivity. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 69 Literaturangaben. Gefördert von: Zhejiang Provincial Natural Science Foundation of China, National Natural Science Foundation of China, "Pioneer" and "Leading Goose" R&D Program of Zhejiang.
Abstract (Originalsprache)
Advances in implantable bioelectronics have improved the interaction between intelligent systems and biological tissues. Yet, the mechanical‐immunological mismatch between rigid electrodes and soft tissues continues to limit long‐term device stability. Here, we present SSPH, an immunocompatible, injectable, conductive hydrogel bridge that enables minimally invasive delivery and stable tissue integration. By forming a compliant interfacial bridge, SSPH reduces mechanical‐biological mismatch and immune stress on electrodes. It is formed by the spontaneous co‐assembly of PEDOT:PSS and the zwitterionic polymer poly(sulfobetaine methacrylate) (PSBMA), resulting in a 3D network stabilized by anion‐π interactions, electrostatic interactions, and PEDOT‐rich nanostructures. This self‐healable architecture allows SSPH to maintain its intrinsic conductive pathways after deformation. Experiments confirmed that SSPH exhibits stable electrochemical properties and favorable immunocompatibility. In an acute muscle injury model, SSPH restored signal transmission across the damaged region, demonstrating its potential to serve as a bridge across disrupted tissue. Furthermore, in both electromyography recording and spinal cord stimulation models, SSPH preserved electrode performance for up to four weeks, supporting reliable bidirectional signal conduction. These results highlight SSPH as a promising, durable, and immunocompatible bridging material for sustained bioelectronic interfaces.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- MOE Key Laboratory of Macromolecular Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou, Zhejiang Province, P. R. China.
- State Key Laboratory of Transvascular Implantation Devices, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, P. R. China.
- Transvascular Implantation Devices Research Institute, Hangzhou, Zhejiang Province, P. R. China.
ORCID-Profile: Jian Ji, Peng Zhang
Förderung
- Zhejiang Provincial Natural Science Foundation of China
- National Natural Science Foundation of China
- "Pioneer" and "Leading Goose" R&D Program of Zhejiang
- State Key Laboratory of Transvascular Implantation Devices
- Transvascular Implantation Devices Research Institute
Zitieren
APA
Zhu, Z., Li, Y., Wang, Y., Yin, Y., Zhou, X., Liu, Z., Chen, K., Yan, Y., Ji, J., & Zhang, P. (2026). An Immunocompatible Conductive Hydrogel Via Anion‐π Interlocking as an Injectable Bridge for Sustained Bioelectronic Interfacing. Advanced Materials, 38(21). https://doi.org/10.1002/adma.72820
Vancouver
Zhu Z, Li Y, Wang Y, Yin Y, Zhou X, Liu Z, et al. An Immunocompatible Conductive Hydrogel Via Anion‐π Interlocking as an Injectable Bridge for Sustained Bioelectronic Interfacing. Advanced Materials. 2026;38(21). doi:10.1002/adma.72820
BibTeX
@article{Zhu2026,
author = {Zhu, Zihao and Li, Yutong and Wang, Yukun and Yin, Yijing and Zhou, Xianchi and Liu, Zuolong and Chen, Kexin and Yan, Yu and Ji, Jian and Zhang, Peng},
title = {An Immunocompatible Conductive Hydrogel Via Anion‐π Interlocking as an Injectable Bridge for Sustained Bioelectronic Interfacing},
journal = {Advanced Materials},
year = {2026},
volume = {38},
number = {21},
doi = {10.1002/adma.72820}
}
EUVIMED