EUVIMEDEUVIMED entdecken
Crossref

Cascade‐Amplified Ratiometric Fluorescent Probe for Time‐Locked Imaging Epilepsy

Xin Wang, Bohan Li, Min Li, Yuncan Chen, Yurui Tang, Aiyan Ji, Jing Zhao, Chenchen Sun, Zhenrong Li, Dan Ni, Yanlong Cheng, Wanbing Sun und 8 weitere

Advanced Materials · 2026-02 · 38 (11)

DOI: 10.1002/adma.202514336 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 05.01.2026. Verfasst von Xin Wang und 19 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmacy, MOE Key Laboratory of Smart Drug Delivery, MOE Innovative Center For New Drug Development of Immune Inflammatory Diseases, Depart…. Hauptthemen laut MEDLINE: Fluorescent Dyes, Epilepsy, Optical Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Key Laboratory of Smart Drug Delivery, Ministry of Education, Key Technologies Research and Development Program, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate localization of the epileptogenic network (EN) is essential for surgical intervention in drug‐resistant epilepsy, which affects over 15 million people globally. However, current approaches are limited by their low specificity, insufficient sensitivity, and challenges in capturing transient epileptiform discharges, which results in surgical success rates ranging from 30% to 70%. Here, we present a cascade‐amplified ratiometric imaging strategy employing an engineered fluorescent polymeric probe (CAR‐FM) that tandemly targets two temporally distinct pathological features within the epileptogenic network: transient acidosis fluctuations triggered by discharges and sustained neuroinflammation. This dual‐cascade amplification enables CAR‐FM to achieve more than a >150‐fold enhancement in fluorescence ratio with markedly improved specificity and sensitivity. In addition, CAR‐FM demonstrates robust applicability across four epilepsy models, which enables time‐locked EN delineation for up to 100 h. In epileptic mouse models, CAR‐FM‐guided resection yields a 67% greater reduction in seizure burden compared to that of conventional electrocorticography. Given its ultrahigh imaging sensitivity and biocompatibility, CAR‐FM offers a clinically translatable strategy for intraoperatively refining EN visualization, which potentially expands the population eligible for epilepsy surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesEpilepsyOptical ImagingAnimalsMiceHumansMale

Stichwörter der Autor:innen

epilepsyfluorescenceimaging‐guided surgerypolymerratiometric imaging

Substanzen

Fluorescent Dyes

Autor:innen und Institutionen

  • School of Pharmacy, MOE Key Laboratory of Smart Drug Delivery, MOE Innovative Center For New Drug Development of Immune Inflammatory Diseases, Department of Pharmacy, Zhongshan Hospital, Fudan University, Shanghai, Chin…
  • Department of Neurology, Huashan Hospital, Fudan University, Shanghai, China.
  • Institute of Brain Intelligence Science and Technology, Fudan University, Shanghai, China.
  • State Key Laboratory of Drug Research, Molecular Imaging Center, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai, China.
  • Department of Neurology and Research Center of Neurology in Second Affiliated Hospital and Key Laboratory of Medical Neurobiology of Zhejiang Province, Zhejiang University School of Medicine, Hangzhou, China.
  • School of Pharmacy, Key Laboratory of Medicinal Chemistry for Natural Resource, Yunnan University, Ministry of Education, Kunming, China.

ORCID-Profile: Cong Li, Xiao Zhu, Cong Wang

Förderung

  • Key Laboratory of Smart Drug Delivery, Ministry of Education
  • Key Technologies Research and Development Program
  • National Natural Science Foundation of China
  • Shanghai Rising-Star Program
  • Medical Engineering fund of Fudan University
  • Strategic Priority Research Program of the Chinese Academy of Sciences

Zitieren

APA

Wang, X., Li, B., Li, M., Chen, Y., Tang, Y., Ji, A., Zhao, J., Sun, C., Li, Z., Ni, D., Cheng, Y., Sun, W., Lei, Z., Wang, J., Vezzani, A., Li, X., Li, C., Zhu, X., Cheng, Z., & Wang, C. (2026). Cascade‐Amplified Ratiometric Fluorescent Probe for Time‐Locked Imaging Epilepsy. Advanced Materials, 38(11). https://doi.org/10.1002/adma.202514336

Vancouver

Wang X, Li B, Li M, Chen Y, Tang Y, Ji A, et al. Cascade‐Amplified Ratiometric Fluorescent Probe for Time‐Locked Imaging Epilepsy. Advanced Materials. 2026;38(11). doi:10.1002/adma.202514336

BibTeX
@article{Wang2026,
  author = {Wang, Xin and Li, Bohan and Li, Min and Chen, Yuncan and Tang, Yurui and Ji, Aiyan and Zhao, Jing and Sun, Chenchen and Li, Zhenrong and Ni, Dan and Cheng, Yanlong and Sun, Wanbing and Lei, Zuhai and Wang, Jing and Vezzani, Annamaria and Li, Xiaoyu and Li, Cong and Zhu, Xiao and Cheng, Zhen and Wang, Cong},
  title = {Cascade‐Amplified Ratiometric Fluorescent Probe for Time‐Locked Imaging Epilepsy},
  journal = {Advanced Materials},
  year = {2026},
  volume = {38},
  number = {11},
  doi = {10.1002/adma.202514336}
}
Kostenlos starten →