Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 21.04.2025. Verfasst von Lei Chen und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry & Academy for Engineering and Technology, Fudan University, Shanghai, 200441, China. Hauptthemen laut MEDLINE: Temperature, Endoscopy, Liver Neoplasms, Thermometers. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, Shanghai Jiao Tong University 2030 Initiative.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Thermal ablation is a common treatment option for early‐stage cancers, but the lack of real‐time temperature imaging feedback method increases the risk of incomplete or excessive ablation. Although ratiometric nanothermometer offers a rapid temperature imaging solution, accurate in vivo signal extraction remains challenging due to the autofluorescence and wavelength‐dependent tissue absorption and scattering. Herein, a time‐resolved ratiometric fluorescence nanothermometer composed of europium and iridium complex with identical working wavelength but distinguishing lifetimes is reported, whose well‐designed structures enable 450 nm excitation of both complexes with a high quantum yield (57.8%). Based on the nanothermometer, accurate signal extraction is realized in whole blood, beneath a 2 cm tissue phantom and a 5 mm pork slice through a time‐resolved ratiometric method. By leveraging the exceptional thermal sensitivity (6.9% K −1 ), high temperature resolution (0.02 K), and clinically relevant temperature range (30–96 °C) of the nanothermometer, a fluorescence temperature endoscopy system is further designed with a real‐time temperature imaging speed of 10 fps, which is applied to minimally invasive temperature monitoring during microwave ablation of liver tumors in rabbits, realizing precise ablation control through dynamic ablation power adjustment. The real‐time and accurate temperature imaging performance of the nanothermometer may offer a new perspective for intraoperative guidance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TemperatureEndoscopyLiver NeoplasmsThermometersAblation TechniquesAnimalsRabbitsOptical ImagingIridiumEuropiumSwineFluorescencePhantoms, ImagingTime Factors

Stichwörter der Autor:innen

endoscopeeuropium complexfluorescence nanothermometerimage‐guided surgeryin vivo temperature imagingthermal ablation

Substanzen

IridiumEuropium

Autor:innen und Institutionen

  • Department of Chemistry & Academy for Engineering and Technology, Fudan University, Shanghai, 200441, China.
  • Department of Radiology, Central Hospital of Xuhui District, Shanghai, 200031, China.
  • College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.
  • School of Chemistry and Chemical Engineering & Institute of Translational Medicine, Shanghai Jiao Tong University, Shanghai, 200240, China.
  • Department of Interventional Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, 200025, China.

ORCID-Profile: Lei Chen, Jiamiao Yin, Yiwei Fan, Yuetian Pei, Fuyou Li

Förderung

  • National Key R&D Program of China
  • National Natural Science Foundation of China
  • Shanghai Jiao Tong University 2030 Initiative
  • Clinical Application and Promotion of Multimodal Precision Ablation in Colorectal Cancer Liver Metastasis
  • National Key Research and Development Program of China

Zitieren

APA

Chen, L., Yin, J., Wang, Y., Fan, Y., Pei, Y., Cai, Z., Yan, W., Hu, D., Wang, Q., Wang, H., Liu, Z., Bian, Z., & Li, F. (2025). Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation. Advanced Materials, 37(28). https://doi.org/10.1002/adma.202503726

Vancouver

Chen L, Yin J, Wang Y, Fan Y, Pei Y, Cai Z, et al. Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation. Advanced Materials. 2025;37(28). doi:10.1002/adma.202503726

BibTeX
@article{Chen2025,
  author = {Chen, Lei and Yin, Jiamiao and Wang, Yiran and Fan, Yiwei and Pei, Yuetian and Cai, Zelun and Yan, Wenchao and Hu, Donghao and Wang, Qingbing and Wang, Huadong and Liu, Zhiwei and Bian, Zuqiang and Li, Fuyou},
  title = {Time‐Resolved Ratiometric Fluorescence Nanothermometer for Real‐Time Endoscopic Temperature Guidance during Tumor Ablation},
  journal = {Advanced Materials},
  year = {2025},
  volume = {37},
  number = {28},
  doi = {10.1002/adma.202503726}
}
Kostenlos starten →