Ternary Compensation Enables High‐sensitive Efficient Upconversion Device for NIR Visualization
Advanced Materials · 2025-01 · 37 (4)
DOI: 10.1002/adma.202412678 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 06.12.2024. Verfasst von Shilong Dong und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry & Chemical Engineering, Frontiers Science Center for Transformative Molecules, State Key Laboratory for Metal Matrix Composite Ma…. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Abstract (Originalsprache)
Beyond the crystalline photodiodes for infrared visualization, with the limitation of opacity and complex lithographic processes, organic upconversion device (UCD) have emerged as a potential alternative. In this research, a ternary compensation strategy is implemented in a non‐fullerene‐based active layer to reduce the dark current of the detector and enhance its detection performance, which enables high‐sensitive efficient upconversion device for near‐infrared light (NIR) visualization. The device achieves an infrared‐to‐visible upconversion efficiency of 16.68% when resolving the 980 nm infrared signal at a power density of 0.4 mW cm −2 . In addition, by replacing the semitransparent matrix electrodes, a large‐area (12.25 cm 2 ) is further fabricated, lightweight (6.5 g containing encapsulation), pixel‐less (equivalent resolution 1270 ppi), and semitransparent (AVT ≈40%) UCD with microsecond response time. The fabricated UCD is demonstrated in pixel‐less active infrared naked‐eye visualization and infrared counter‐surveillance, fostering the advancement of infrared visualization technology.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Chemistry & Chemical Engineering, Frontiers Science Center for Transformative Molecules, State Key Laboratory for Metal Matrix Composite Materials, Shanghai Jiao Tong University, Shanghai, 200240, China.
ORCID-Profile: Xuesong Jiang
Zitieren
APA
Dong, S., Li, J., Ma, T., Zhang, M., Zhu, L., Gao, X., Ma, M., Yuan, W., Wang, Z., Liu, F., & Jiang, X. (2025). Ternary Compensation Enables High‐sensitive Efficient Upconversion Device for NIR Visualization. Advanced Materials, 37(4). https://doi.org/10.1002/adma.202412678
Vancouver
Dong S, Li J, Ma T, Zhang M, Zhu L, Gao X, et al. Ternary Compensation Enables High‐sensitive Efficient Upconversion Device for NIR Visualization. Advanced Materials. 2025;37(4). doi:10.1002/adma.202412678
BibTeX
@article{Dong2025,
author = {Dong, Shilong and Li, Jin and Ma, Tianjiao and Zhang, Ming and Zhu, Lei and Gao, Xiaxin and Ma, Manping and Yuan, Wenqiang and Wang, Zaiyu and Liu, Feng and Jiang, Xuesong},
title = {Ternary Compensation Enables High‐sensitive Efficient Upconversion Device for NIR Visualization},
journal = {Advanced Materials},
year = {2025},
volume = {37},
number = {4},
doi = {10.1002/adma.202412678}
}
EUVIMED