EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Enhanced Colorimetric Detection of Volatile Organic Compounds Using a Dye‐Incorporated Photonic Crystal‐Based Sensor Array

So Hee Nah iD, Jong Bin Kim iD, Hiu Ning Tiffany Chui, Yeonjoon Suh, Shu Yang iD

Advanced Materials · 2024-11 · 36 (46)

DOI: 10.1002/adma.202409297 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 10.09.2024. Verfasst von So Hee Nah und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, University of Pennsylvania, 3231 Walnut Street, Philadelphia, PA, 19104, USA. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: OrthoNu LLC and Center for Precision Engineering for Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Chemoresponsive dyes offer the potential to selectively detect volatile organic compounds (VOCs) unique to certain disease states. Among different VOC sensing techniques, colorimetric sensing offers the advantage of facile recognition. However, it is often challenging to discern the color changes by the naked eye. Here, highly sensitive colorimetric VOC sensor arrays from dye‐incorporated colloidal photonic crystals (dye‐cPhCs) are reported. cPhCs are scalably fabricated on a 4‐inch wafer by spin‐coating of silica nanoparticles (NPs) dispersed in a photo‐cross‐linkable monomer, where the gradient shear flow along the film thickness creates densely‐packed square arrays of NPs in the top layers, whereas the bulk is quasi‐amorphous with larger periodicities. The broadened reflection peak allows for augmented dye absorption originating from the overlap between the photonic bandgap edge of the cPhC and the dye absorption peak, leading to a more noticeable color change upon exposure to VOCs. The sensor array generates distinct color difference maps for acetaldehyde, acetone, and acetic acid, respectively, without any data amplification. The limit of detection for acetaldehyde, acetone, and acetic acid is 1, 0.1, and 0.02 ppm, respectively. Moreover, VOC can be diagonalized by visually intuitive pattern recognition, and principal component analysis at reduced dimensionality is demonstrated.

Schlagwörter

Stichwörter der Autor:innen

colorimetric arraysdyesphotonic crystalssensorsvolatile organic compounds

Autor:innen und Institutionen

  • Department of Materials Science and Engineering, University of Pennsylvania, 3231 Walnut Street, Philadelphia, PA, 19104, USA.
  • Department of Electrical and Systems Engineering, University of Pennsylvania, 209 S 33rd Street, Philadelphia, PA, 19104, USA.

ORCID-Profile: So Hee Nah, Jong Bin Kim, Shu Yang

Förderung

  • OrthoNu LLC and Center for Precision Engineering for Health

Zitieren

APA

Nah, S. H., Kim, J. B., Chui, H. N. T., Suh, Y., & Yang, S. (2024). Enhanced Colorimetric Detection of Volatile Organic Compounds Using a Dye‐Incorporated Photonic Crystal‐Based Sensor Array. Advanced Materials, 36(46). https://doi.org/10.1002/adma.202409297

Vancouver

Nah SH, Kim JB, Chui HNT, Suh Y, Yang S. Enhanced Colorimetric Detection of Volatile Organic Compounds Using a Dye‐Incorporated Photonic Crystal‐Based Sensor Array. Advanced Materials. 2024;36(46). doi:10.1002/adma.202409297

BibTeX
@article{Nah2024,
  author = {Nah, So Hee and Kim, Jong Bin and Chui, Hiu Ning Tiffany and Suh, Yeonjoon and Yang, Shu},
  title = {Enhanced Colorimetric Detection of Volatile Organic Compounds Using a Dye‐Incorporated Photonic Crystal‐Based Sensor Array},
  journal = {Advanced Materials},
  year = {2024},
  volume = {36},
  number = {46},
  doi = {10.1002/adma.202409297}
}
Kostenlos starten →