EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids

Sheng Wu iD, Guangyu Zhou, Yafen Wu, Puxian Xiong iD, Binli Xiao, Zhiyao Zhou, Yao Xiao, Peishan Shao, Shouping Wang, Zhigang Shao, Yinzhen Wang, Feifei Wang

Advanced Materials · 2024-12 · 36 (50)

DOI: 10.1002/adma.202408508 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 06.11.2024. Verfasst von Sheng Wu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Guangdong Basic Research Center of Excellence for Structure and Fundamental Interactions of Matter, Guangdong Provincial Key Laboratory of Quantum En…. Hauptthemen laut MEDLINE: Blood Glucose, Lipids. Die Arbeit wurde bisher 97-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Guangzhou Basic and Applied Basic Research Foundation, Special Funds for the Cultivation of Guangdong College Students' Scientific and Technological Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mechanoluminescence (ML) materials, known for their ability to convert mechanical energy into light, are increasingly recognized for their potential applications, such as in intelligent stress sensing, in vivo bioimaging, and stress non‐destructive monitoring. However, the low signal‐to‐noise ratio (SNR) and narrow‐band emission of single‐defect‐induced ML materials usually limit their biological‐related practical applications. Here, these limitations will be addressed by modulating the microstructure evolution in Y 3 Ga 3 MgSiO 12 :Cr 3+ through the [Si 4+ +Mg 2+ ] → [Ga 3+ +Ga 3+ ] chemical substitution strategy. Density functional theory (DFT) calculation reveals the defect types and dynamic charge migration processes. In addition, Y 3 Ga 3 MgSiO 12 : Cr 3+ with continuously distributed “shallow‐deep” defects (0.68–1.61 eV) can avoid persistent luminescence (PersL) and bright‐field environment interference. Herein, such high SNR near‐infrared broadband ML emission may provide a reliable way for high‐quality biological non‐destructive sensing and detection. Finally, benefiting from the different absorption of ML signals in glucose/lipid, one may find a novel non‐invasive blood glucose/lipid testing technology in patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood GlucoseLipidsHumansLuminescent MeasurementsSignal-To-Noise RatioDensity Functional TheoryInfrared RaysLuminescent Agents

Stichwörter der Autor:innen

Cr3+multiple defectnear infrared mechanoluminescencenon‐destructive detectionpersistent luminescence

Substanzen

Blood GlucoseLipidsLuminescent Agents

Autor:innen und Institutionen

  • Guangdong Basic Research Center of Excellence for Structure and Fundamental Interactions of Matter, Guangdong Provincial Key Laboratory of Quantum Engineering and Quantum Materials, Guangdong-Hong Kong Joint Laboratory…
  • Department of Anesthesiology;, Guangdong Provincial Key Laboratory of Major Obstetric Diseases; Guangdong Provincial Clinical Research Center for Obstetrics and Gynecology; The Third Afliated Hospital, Guangzhou Medical…
  • Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, 999077, China.
  • Guangdong Provincial Key Laboratory of Fiber Laser Materials and Applied Techniques, Guangdong Engineering Technology Research and Development Center of Special Optical Fiber Materials and Devices, State Key Laboratory…
  • Materials Innovation Institute for Life Sciences and Energy (MILES), The University of Hong Kong, Hong Kong, 999077, China.

ORCID-Profile: Sheng Wu, Puxian Xiong

Förderung

  • National Natural Science Foundation of China
  • Guangzhou Basic and Applied Basic Research Foundation
  • Special Funds for the Cultivation of Guangdong College Students' Scientific and Technological Innovation
  • The Fundamental and Applied Basic Research Foundation of Guangdong Province
  • Early Career Scheme, RGC

Zitieren

APA

Wu, S., Zhou, G., Wu, Y., Xiong, P., Xiao, B., Zhou, Z., Xiao, Y., Shao, P., Wang, S., Shao, Z., Wang, Y., & Wang, F. (2024). Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids. Advanced Materials, 36(50). https://doi.org/10.1002/adma.202408508

Vancouver

Wu S, Zhou G, Wu Y, Xiong P, Xiao B, Zhou Z, et al. Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids. Advanced Materials. 2024;36(50). doi:10.1002/adma.202408508

BibTeX
@article{Wu2024,
  author = {Wu, Sheng and Zhou, Guangyu and Wu, Yafen and Xiong, Puxian and Xiao, Binli and Zhou, Zhiyao and Xiao, Yao and Shao, Peishan and Wang, Shouping and Shao, Zhigang and Wang, Yinzhen and Wang, Feifei},
  title = {Multiple Defect‐Induced High‐Resolution Near‐Infrared Mechanoluminescent Materials for Non‐Destructive Detection of Blood Glucose and Lipids},
  journal = {Advanced Materials},
  year = {2024},
  volume = {36},
  number = {50},
  doi = {10.1002/adma.202408508}
}
Kostenlos starten →