Fachartikel in der Zeitschrift Advanced Materials, 2024. Verfasst von Mei Yang und 17 weiteren Autor:innen. Beteiligte Einrichtung: Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, NHC Key laboratory of Myopia and Related Eye Diseases, Key Laboratory of Myopia an…. Hauptthemen laut MEDLINE: Riboflavin, Keratoconus, Needles, Cross-Linking Reagents. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Shanghai Science and Technology, EYE & ENT Hospital of Fudan University High-level Talents Program, Clinical Research Plan of SHDC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a novel customized corneal cross‐linking (CXL) treatment is explored that utilizes microneedles (MNs) for targeted riboflavin (RF) administration prior to the CXL procedure. Unlike the conventional “one‐size‐fits‐all” approach, this protocol offers an option for more precise and efficacious treatment. To simulate a customized corneal crosslinking technique, four distinct microneedle (MN) molds designs, including circular, semi‐circular, annular and butterfly shaped, are crafted for loading an optimized RF‐hyaluronic acid solution and for the subsequent fabrication of MN arrays with varying morphologies. These MNs can gently puncture the corneal epithelium while preserving the integrity of the underlying stromal layer. Following the application of these microneedles, RF solution is replenished to enhance the RF content within the stroma through the punctures created by the MNs, resulting in exceptional customized corneal cross‐linking effects that are comparable to the conventional epi‐off CXL protocol. Additionally, it flattened the corneal curvature within the treated zone and facilitated rapid postoperative recovery of corneal tissue. These findings suggest that the integration of customized microneedle RF delivery with corneal crosslinking technology represents a potential novel treatment modality, holding promise for the tailored treatment of corneal pathologies, and offering a more precise and efficient alternative to traditional methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RiboflavinKeratoconusNeedlesCross-Linking ReagentsAnimalsCorneaHyaluronic AcidRabbitsHumansCollagenCorneal StromaDrug Delivery SystemsCorneal Cross-Linking

Stichwörter der Autor:innen

customized corneal cross‐linkingmicroneedlesriboflavintargeted administration

Substanzen

RiboflavinCross-Linking ReagentsHyaluronic AcidCollagen

Autor:innen und Institutionen

  • Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, NHC Key laboratory of Myopia and Related Eye Diseases, Key Laboratory of Myopia and Related Eye Diseases, Chinese Academy of Medical Sciences, Shanghai…
  • School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, 325027, China.
  • School of Optometry and Vision Sciences, Cardiff Institute for Tissue Engineering and Repair School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Redwood Building, King Edward VII Avenue, Cardiff, CF10 3N…

ORCID-Profile: Jinhai Huang

Förderung

  • Shanghai Science and Technology
  • EYE & ENT Hospital of Fudan University High-level Talents Program
  • Clinical Research Plan of SHDC
  • Medical Engineering fund of Fudan University
  • Project of Shanghai Xuhui District Science and Technology
  • Shanghai Anticancer Association EYAS PROJECT
  • Program for Professor of Special Appointment (Eastern Scholar) at Shanghai Institutions of Higher Learning
  • National Natural Science Foundation of China

Zitieren

APA

Yang, M., Pan, H., Chen, T., Chen, X., Ning, R., Ye, Q., Chen, A., Li, J., Li, S., Zhao, N., Wu, Y., Fu, X., Meek, K. M., Chen, L., Wang, X., Chen, Z., Zhou, X., & Huang, J. (2024). Customized Corneal Cross‐Linking with Microneedle‐Mediated Riboflavin Delivery for Keratoconus Treatment. Advanced Materials. https://doi.org/10.1002/adma.202408136

Vancouver

Yang M, Pan H, Chen T, Chen X, Ning R, Ye Q, et al. Customized Corneal Cross‐Linking with Microneedle‐Mediated Riboflavin Delivery for Keratoconus Treatment. Advanced Materials. 2024. doi:10.1002/adma.202408136

BibTeX
@article{Yang2024,
  author = {Yang, Mei and Pan, Hongxian and Chen, Tingting and Chen, Xin and Ning, Rui and Ye, Qianfang and Chen, Aodong and Li, Jiawei and Li, Siheng and Zhao, Nan and Wu, Yue and Fu, Xueyu and Meek, Keith M and Chen, Lingxin and Wang, Xiaoying and Chen, Zhongxing and Zhou, Xingtao and Huang, Jinhai},
  title = {Customized Corneal Cross‐Linking with Microneedle‐Mediated Riboflavin Delivery for Keratoconus Treatment},
  journal = {Advanced Materials},
  year = {2024},
  doi = {10.1002/adma.202408136}
}
Kostenlos starten →