EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Stretchable Device for Simultaneous Measurements of Contractility and Electrophysiology of Neuromuscular Tissue in the Gastrointestinal Tract

Poppy Oldroyd, Sophie Oldroyd, Michelle Meng, Rajesh Makwana, Gareth Sanger, David Bulmer, George G Malliaras, Róisín M Owens iD

Advanced Materials · 2024

DOI: 10.1002/adma.202312735 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials, 2024. Verfasst von Poppy Oldroyd und 7 weiteren Autor:innen. Beteiligte Einrichtung: Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK. Hauptthemen laut MEDLINE: Polystyrenes, Dimethylpolysiloxanes. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Air Force Office of Scientific Research, AstraZeneca, Royal Commission for the Exhibition of 1851.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Devices interfacing with biological tissues can provide valuable insights into function, disease, and metabolism through electrical and mechanical signals. However, certain neuromuscular tissues, like those in the gastrointestinal tract, undergo significant strains of up to 40%. Conventional inextensible devices cannot capture the dynamic responses in these tissues. This study introduces electrodes made from poly(3,4‐ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and polydimethylsiloxane (PDMS) that enable simultaneous monitoring of electrical and mechanical responses of gut tissue. The soft PDMS layers conform to tissue surfaces during gastrointestinal movement. Dopants, including Capstone FS‐30 and polyethylene glycol, are explored to enhance the conductivity, electrical sensitivity to strain, and stability of the PEDOT:PSS. The devices are fabricated using shadow masks and solution‐processing techniques, providing a faster and simpler process than traditional clean‐room‐based lithography. Tested on ex vivo mouse colon and human stomach, the device recorded voltage changes of up to 300 µV during contraction and distension consistent with muscle activity, while simultaneously recording resistance changes of up to 150% due to mechanical strain. These devices detect and respond to chemical stimulants and blockers, and can induce contractions through electrical stimulation. They hold great potential for studying and treating complex disorders like irritable bowel syndrome and gastroparesis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolystyrenesDimethylpolysiloxanesAnimalsMiceHumansMuscle ContractionElectrodesGastrointestinal TractStomachColonElectric ConductivityPolymersElectrophysiological PhenomenaBridged Bicyclo Compounds, HeterocyclicThiophenes

Stichwörter der Autor:innen

PDMSPEDOT:PSSbioelectronicselectrodeselectrophysiologyorganicstretchable

Substanzen

PolystyrenesDimethylpolysiloxanesbaysilonpoly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate)PolymersBridged Bicyclo Compounds, HeterocyclicThiophenespoly(3,4-ethylene dioxythiophene)

Autor:innen und Institutionen

  • Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge, CB3 0FA, UK.
  • Department of Chemical Engineering and Biotechnology, University of Cambridge, Cambridge, CB3 0AS, UK.
  • Department of Pharmacology, Tennis Ct Rd, University of Cambridge, Cambridge, CB2 1PD, UK.
  • Blizard Institute, Queen Mary University of London, Cambridge, E1 2AT, UK.

ORCID-Profile: Róisín M Owens

Förderung

  • Air Force Office of Scientific Research
  • AstraZeneca
  • Royal Commission for the Exhibition of 1851
  • Engineering and Physical Sciences Research Council, Centre for Doctoral Training in Sensor Technologies for a Healthy and Sustainable Future
  • Engineering and Physical Sciences Research Council, Johnson Matthey

Zitieren

APA

Oldroyd, P., Oldroyd, S., Meng, M., Makwana, R., Sanger, G., Bulmer, D., Malliaras, G. G., & Owens, R. M. (2024). Stretchable Device for Simultaneous Measurements of Contractility and Electrophysiology of Neuromuscular Tissue in the Gastrointestinal Tract. Advanced Materials. https://doi.org/10.1002/adma.202312735

Vancouver

Oldroyd P, Oldroyd S, Meng M, Makwana R, Sanger G, Bulmer D, et al. Stretchable Device for Simultaneous Measurements of Contractility and Electrophysiology of Neuromuscular Tissue in the Gastrointestinal Tract. Advanced Materials. 2024. doi:10.1002/adma.202312735

BibTeX
@article{Oldroyd2024,
  author = {Oldroyd, Poppy and Oldroyd, Sophie and Meng, Michelle and Makwana, Rajesh and Sanger, Gareth and Bulmer, David and Malliaras, George G and Owens, Róisín M},
  title = {Stretchable Device for Simultaneous Measurements of Contractility and Electrophysiology of Neuromuscular Tissue in the Gastrointestinal Tract},
  journal = {Advanced Materials},
  year = {2024},
  doi = {10.1002/adma.202312735}
}
Kostenlos starten →