EUVIMEDEUVIMED entdecken
Crossref

Measuring Solvent Exchange in Silica Nanoparticles with Rotor‐Based Fluorophore

Xuejun Cheng, Yingming Pu, Songtao Ye, Xiao Xiao, Xin Zhang, Hongyu Chen iD

Advanced Materials · 2024-01 · 36 (3)

DOI: 10.1002/adma.202305779 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Materials, online erschienen am 27.11.2023. Verfasst von Xuejun Cheng und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang, 310027, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Hangzhou Municipal Funding, Team of Innovation, Natural Science Foundation of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measuring the diffusivity of molecules is the first step toward understanding their dependence and controlling diffusion, but the challenge increases with the decrease of molecular size, particularly for non‐fluorescent and non‐reactive molecules such as solvents. Here, the capability to monitor the solvent exchange process within the micropores of silica with millisecond time resolution is demonstrated, by simply embedding a rotor‐based fluorophore (thioflavin T) in colloidal silica nanoparticles. Basically, the silica provides an extreme case of viscous microenvironment, which is affected by the polarity of the solvents. The fluorescence intensity traces can be well fitted to the Fickian diffusion model, allowing analytical solution of the diffusion process, and revealing the diffusion coefficients. The validation experiments, involving the water‐to‐ethanol and ethanol‐to‐water solvent exchange, the comparison of different drying conditions, and the variation in the degree of cross‐linking in silica, confirmed the effectiveness and sensitivity of this method for characterizing diffusion in silica micropores. This work focuses on the method development of measuring diffusivity and the high temporal resolution in tracking solvent exchange dynamics over a short distance (within 165 nm) opens enormous possibilities for further studies.

Schlagwörter

Stichwörter der Autor:innen

fluorescencesilicasolvent diffusionstopped-flowthioflavin T

Autor:innen und Institutionen

  • Department of Chemistry, Zhejiang University, Hangzhou, Zhejiang, 310027, China.
  • Department of Chemistry, School of Science and Research Center for Industries of the Future, Westlake University, 600 Dunyu Road, Hangzhou, Zhejiang, 310024, China.
  • Institute of Natural Sciences, Westlake Institute for Advanced Study, 18 Shilongshan Road, Hangzhou, Zhejiang, 310024, China.

ORCID-Profile: Hongyu Chen

Förderung

  • National Natural Science Foundation of China
  • Hangzhou Municipal Funding, Team of Innovation
  • Natural Science Foundation of Zhejiang Province
  • Foundation of Westlake University

Zitieren

APA

Cheng, X., Pu, Y., Ye, S., Xiao, X., Zhang, X., & Chen, H. (2024). Measuring Solvent Exchange in Silica Nanoparticles with Rotor‐Based Fluorophore. Advanced Materials, 36(3). https://doi.org/10.1002/adma.202305779

Vancouver

Cheng X, Pu Y, Ye S, Xiao X, Zhang X, Chen H. Measuring Solvent Exchange in Silica Nanoparticles with Rotor‐Based Fluorophore. Advanced Materials. 2024;36(3). doi:10.1002/adma.202305779

BibTeX
@article{Cheng2024,
  author = {Cheng, Xuejun and Pu, Yingming and Ye, Songtao and Xiao, Xiao and Zhang, Xin and Chen, Hongyu},
  title = {Measuring Solvent Exchange in Silica Nanoparticles with Rotor‐Based Fluorophore},
  journal = {Advanced Materials},
  year = {2024},
  volume = {36},
  number = {3},
  doi = {10.1002/adma.202305779}
}
Kostenlos starten →