EUVIMEDEUVIMED entdecken
Crossref

Multi‐Material 3D Printed Conductive/ Neat TPU Dry Electrodes for ECG Monitoring Wearable Applications

Emmanouil Porfyrakis iD, Vladimiros Liontos, Stefanos Maltezos, Ioannis Kavvadias iD, Konstantinos Tsongas, Panagiotis Vosniadis, Nikos Konofaos, Evangelos K Evangelou, Lazaros Tzounis

Advanced Healthcare Materials · 2026

DOI: 10.1002/adhm.71261 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, 2026. Verfasst von Emmanouil Porfyrakis und 8 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering Department, Hellenic Mediterranean University, Heraklion, Crete, Greece. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Printing, Three-Dimensional, Polyurethanes, Electrocardiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 59 Literaturangaben. Gefördert von: Hellenic Foundation for Research and Innovation, Advanced Photonic PRocesses for novel sOlar energy hArvesting teCHnologies, A First of a kind Hub for circularity demonstrator for Attica and peripheral regions.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The limitations of traditional gel‐based Ag/AgCl electrodes, such as skin irritation, unsuitability for long‐term monitoring, etc., have spurred the development of next‐generation “dry” electrodes for bioelectricity monitoring applications. This study reports the fabrication of high‐performance and low‐cost thermoplastic elastomer multi‐material 3D printed (3DP) dry electrodes, utilizing Fused Filament Fabrication (FFF). The electrodes consist of neat and conductive thermoplastic polyurethane (cTPU) simultaneously printed to incorporate the conductive material properties into the electrodes’ bulk structure, as well as “tune” the compliance, stretchability, and flexibility with respect to the human skin stiffness. Different electrode designs are proposed to optimize skin conformity, employing nature‐inspired triply periodic minimal surface (TPMS) geometries, namely, gyroid (G) and square honeycomb (SH), with a 3 mm unit cell size. The final electrodes are characterized through thermogravimetric analyses, tensile testing, cyclic bending, and electrode‐skin impedance, while different ECG signal acquisition scenarios are demonstrated, i.e., stationary, 24 h monitoring, standing, and walking. The multi‐material gyroid electrode exhibited the lowest electrode‐skin impedance (298 kΩ at 20 Hz) and the highest ECG signal quality. The proposed multi‐material structure and TPMS design strategy enable a scalable route to comfortable, reusable, and high‐performance electrodes by spatially combining conductivity and skin‐compliant mechanics, supporting continuous bioelectricity monitoring in wearable applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesPrinting, Three-DimensionalPolyurethanesElectrocardiographyElectrodesHumansElectric Conductivity

Stichwörter der Autor:innen

3D Printingconductive polymer nanocompositesdry electrodeselectrocardiography (ECG)fused filament fabrication (FFF)long‐term monitoringsurface biopotential monitoringwearable electronics

Substanzen

Polyurethanes

Autor:innen und Institutionen

  • Mechanical Engineering Department, Hellenic Mediterranean University, Heraklion, Crete, Greece.
  • Department of Physics, University of Ioannina, Ioannina, Greece.
  • Department of Civil Engineering, Democritus University of Thrace, Xanthi, Greece.
  • Department of Industrial Engineering and Management School of Engineering, International Hellenic University, Thessaloniki, Greece.
  • Department of Informatics, Aristotle University of Thessaloniki, Biology Building, Main University Campus, Thessaloniki, Greece.
  • Printed Electronic Devices of Things P.C. (PDoT), Volos, Greece.

ORCID-Profile: Emmanouil Porfyrakis, Ioannis Kavvadias

Förderung

  • Hellenic Foundation for Research and Innovation
  • Advanced Photonic PRocesses for novel sOlar energy hArvesting teCHnologies
  • A First of a kind Hub for circularity demonstrator for Attica and peripheral regions
  • Soft, wearable, assistive garments for human empowerment

Zitieren

APA

Porfyrakis, E., Liontos, V., Maltezos, S., Kavvadias, I., Tsongas, K., Vosniadis, P., Konofaos, N., Evangelou, E. K., & Tzounis, L. (2026). Multi‐Material 3D Printed Conductive/ Neat TPU Dry Electrodes for ECG Monitoring Wearable Applications. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.71261

Vancouver

Porfyrakis E, Liontos V, Maltezos S, Kavvadias I, Tsongas K, Vosniadis P, et al. Multi‐Material 3D Printed Conductive/ Neat TPU Dry Electrodes for ECG Monitoring Wearable Applications. Advanced Healthcare Materials. 2026. doi:10.1002/adhm.71261

BibTeX
@article{Porfyrakis2026,
  author = {Porfyrakis, Emmanouil and Liontos, Vladimiros and Maltezos, Stefanos and Kavvadias, Ioannis and Tsongas, Konstantinos and Vosniadis, Panagiotis and Konofaos, Nikos and Evangelou, Evangelos K and Tzounis, Lazaros},
  title = {Multi‐Material 3D Printed Conductive/ Neat TPU Dry Electrodes for ECG Monitoring Wearable Applications},
  journal = {Advanced Healthcare Materials},
  year = {2026},
  doi = {10.1002/adhm.71261}
}
Kostenlos starten →