EUVIMEDEUVIMED entdecken
Crossref

Responsive Polyphenolic Coating Reduces the Risk of Peri‐Implantitis Through Antibacterial Activity, Immunomodulation, and Enhanced Osseointegration

Manqing Liu iD, Junmei Song, Deqian Tang, Tianyou Wang iD, Junbin Wei, Junda Li, Jiayun Xu, Yuming Xu, Qianmin Ou, Chunyu Zhang, Zhipeng Gu iD, Jinming Wang iD

Advanced Healthcare Materials · 2026-03 · 15 (12)

DOI: 10.1002/adhm.202504797 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advanced Healthcare Materials, online erschienen am 04.01.2026. Verfasst von Manqing Liu und 11 weiteren Autor:innen. Beteiligte Einrichtung: Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University and Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, 51…. Hauptthemen laut MEDLINE: Osseointegration, Anti-Bacterial Agents, Peri-Implantitis, Polyphenols. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 69 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and the Technology Program of Nansha, China, Natural Science Foundation of Sichuan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Implant failure is primarily caused by infection and dysregulated immune responses, highlighting the need to develop implants with tissue‐friendly properties. This study introduces a novel one‐step strategy for applying a polyphenol–aminoglycoside (PA) coating on various implant substrates, including titanium, in a simple and efficient manner. The multifunctional PA coating can reduce implant failure through its strong antibacterial, immunomodulatory, and osteoinductive activities. By eliminating bacterial infection, promoting the M2 macrophage phenotype, and restoring oxidative balance, PA‐coated implants create a favorable osteoimmune microenvironment that supports the osteogenic differentiation of bone marrow mesenchymal stem cells. Furthermore, the PA‐coated implants exhibit potent osseointegration in vivo. Collectively, these findings indicate that surface modification with a PA coating represents a promising strategy to meet the clinical requirements of next‐generation dental and orthopedic implants in complex clinical environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OsseointegrationAnti-Bacterial AgentsPeri-ImplantitisPolyphenolsCoated Materials, BiocompatibleImmunomodulationAnimalsMiceTitaniumMesenchymal Stem CellsOsteogenesisMacrophages

Stichwörter der Autor:innen

antibacterial therapydental implantsosseointegrationosteoimmunomodulationpolyphenolic coatings

Substanzen

Anti-Bacterial AgentsPolyphenolsCoated Materials, BiocompatibleTitanium

Autor:innen und Institutionen

  • Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University and Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, 510055, China.
  • College of Polymer Science and Engineering, State Key Laboratory of Advanced Polymer Materials, Sichuan University, Chengdu, 610065, China.
  • Department of Stomatology, The Fifth Affiliated Hospital of Sun Yat-Sen University, The Fifth Affiliated Hospital of Sun Yat-sen University, 52 Meihua East Road, Xiangzhou District, Zhuhai, Guangdong Province, China.
  • GuangDong Janus Biotechnology Co.,Ltd., Heung Kong International Technology Innovation Centre, Guangzhou, 518000, China.

ORCID-Profile: Manqing Liu, Tianyou Wang, Zhipeng Gu, Jinming Wang

Förderung

  • National Natural Science Foundation of China
  • Science and the Technology Program of Nansha, China
  • Natural Science Foundation of Sichuan Province
  • Guangdong Basic and Applied Basic Research Foundation
  • Open Funding of Guangdong Provincial Key Laboratory of Stomatology
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Liu, M., Song, J., Tang, D., Wang, T., Wei, J., Li, J., Xu, J., Xu, Y., Ou, Q., Zhang, C., Gu, Z., & Wang, J. (2026). Responsive Polyphenolic Coating Reduces the Risk of Peri‐Implantitis Through Antibacterial Activity, Immunomodulation, and Enhanced Osseointegration. Advanced Healthcare Materials, 15(12). https://doi.org/10.1002/adhm.202504797

Vancouver

Liu M, Song J, Tang D, Wang T, Wei J, Li J, et al. Responsive Polyphenolic Coating Reduces the Risk of Peri‐Implantitis Through Antibacterial Activity, Immunomodulation, and Enhanced Osseointegration. Advanced Healthcare Materials. 2026;15(12). doi:10.1002/adhm.202504797

BibTeX
@article{Liu2026,
  author = {Liu, Manqing and Song, Junmei and Tang, Deqian and Wang, Tianyou and Wei, Junbin and Li, Junda and Xu, Jiayun and Xu, Yuming and Ou, Qianmin and Zhang, Chunyu and Gu, Zhipeng and Wang, Jinming},
  title = {Responsive Polyphenolic Coating Reduces the Risk of Peri‐Implantitis Through Antibacterial Activity, Immunomodulation, and Enhanced Osseointegration},
  journal = {Advanced Healthcare Materials},
  year = {2026},
  volume = {15},
  number = {12},
  doi = {10.1002/adhm.202504797}
}
Kostenlos starten →